Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sano, Hirotakaa; * | Tokunaga, Masakoa | Noguchi, Moriyukia | Inawashiro, Takashia | Irie, Taichia | Abe, Hirooa | Yokobori Jr, A. Toshimitsub
Affiliations: [a] Division of Orthopedics, Sendai City Hospital, Sendai, Japan | [b] Strategic Innovation Research Hub Laboratory of Strength of Materials and Science, Teikyo University, Tokyo, Japan
Correspondence: [*] Corresponding author: Hirotaka Sano, Senior Staff, Division of Orthopedics, Sendai City Hospital, 1-1-1, Asuto-Nagamachi, Taihaku-ku, Sendai, 982-8502, Japan. Tel.: +81-22-308-7111; Fax: +81-22-308-7153; E-mail: [email protected].
Abstract: Background:Retearing mechanism after transosseous equivalent (TOE) rotator cuff repair has not been fully clarified yet. Objective:The purposes of this study were to compare the stress distribution pattern in the tendon stump between knotted and knotless TOE repair and to investigate the role of suture tension applied during medial knot tying using a 3-dimensional finite element (3D-FE) method. Methods:Both knotted and knotless TOE repairs were simulated on the 3D-FE human rotator cuff tear model. Elastic analysis was performed to compare the stress distribution pattern inside the tendon between the two models. The amount of compressive load applied to the medial-row sutures was then changed as 0, 20, 40, 60, 80, and 100 N in the knotted model. Results:Knotted model demonstrated more distinct stress concentration inside the tendon around medial-row sutures than the knotless model. Mean von Mises equivalent stress in this area in the 0, 20, 40, 60, 80, and 100 N models was 0.26, 0.35, 0.50, 0.70, 1.11, and 1.14 MPa, respectively. Conclusions:In the knotted TOE repair, tight medial knot tying might cause a high stress concentration around medial knots, which may constitute one of the pathogenetic factors of postoperative retearing at this site.
Keywords: Rotator cuff tear, transosseous equivalent repair, medial knot tying, retearing, stress concentration, finite element method
DOI: 10.3233/BME-171673
Journal: Bio-Medical Materials and Engineering, vol. 28, no. 3, pp. 267-277, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]