Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Current Research Progress of Ceramic Biomaterials in Japan
Guest editors: Kimihiro Yamashita and Masayuki Okazaki
Article type: Research Article
Authors: Kohata, Kazuhiroa | Itoh, Soichiroa; b; * | Horiuchi, Naohiroa | Yoshioka, Tarob | Yamashita, Kimihiroa
Affiliations: [a] Department of Inorganic Materials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan | [b] Department of Orthopedic Surgery, Kawakita General Hospital, 1-7-3 Asagaya-kita, Suginami, Tokyo 166-8588, Japan
Correspondence: [*] Corresponding author. Tel.: +81 3 5280 8016; Fax: +81 3 5280 8125; E-mail: [email protected].
Abstract: We characterized the electrical properties of living bone obtained from patients who had undergone total hip arthroplasty (THA) or hemiarthroplasty by means of analysis of the electrically polarized and nonpolarized bone specimens, and we discussed the role of an organic and inorganic matrix of human bone in bone piezoelectricity. We used human femoral neck bone that was harvested during THA for advanced osteoarthritis of the hip joint (OA group) and hemiarthroplasty for femoral neck fracture (FNF group). The specimens were scanned to evaluate the cancellous bone structures using micro-computed tomography, and we quantified the carbonic acid by attenuated total reflection (ATR) spectra to estimate carbonate apatite. The stored electrical charge in the electrically polarized and nonpolarized bone specimens were calculated using thermally stimulated depolarized current (TSDC) measurements. Each TSDC curve in the groups had peaks at 100°C, 300°C and 500°C, which may be attributed to collagen, carbonate apatite and hydroxyapatite, respectively. It is suggested that organic substances are more effectively electrically polarized than apatite minerals by the polarization at room temperature and that the stored charge in living bone may be affected not only by total bone mass but also by bone quality, including 3-dimensional structure and structural component.
Keywords: Electrical property, human bone, electrical polarization, osteoarthritis, osteoporosis, proximal femur
DOI: 10.3233/BME-171657
Journal: Bio-Medical Materials and Engineering, vol. 28, no. 1, pp. 65-74, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]