Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Korossis, Sotiris A. | Fisher, John | Ingham, Eileen
Affiliations: Department of Mechanical Engineering, Leeds University, Leeds, LS2 9JT, UK
Abstract: The second most common major heart operation in the western world is valve replacement. Any one of the four heart valves may become either so stenotic or regurgitant that it needs to be replaced in order to restore normal heart function. Although replacement surgery of dysfunctional heart valves has a very high success rate, it can provide the surgeon with a difficult decision regarding the choice of a suitable prosthesis for the individual patient. Over the years many different types of artificial heart valves have been devised. Surgeons typically deal with a heart valve replacement by installing a mechanical prosthesis or by using a bioprosthetic valve, hand‐crafted from animal tissue. Least commonly, valves can be taken from human organ donors. Mechanical valve substitutes have a long fatigue life but the central flow occluders often induce blood cell trauma. Tissue substitutes have an unimpeded central orifice when open, cause minimal cell damage but have a relatively short fatigue life, especially in children where calcification may be a major problem. More recently alternative materials, such as polyurethane, have been used in artificial heart valve design while the new concept of tissue‐engineering has enhanced the prospects towards an ideal cardiac valve replacement. Today’s artificial valves are designed with a better understanding of the cardiovascular system with the aid of computers. Advances in computer software have allowed simulations of fluid flows through valve substitutes, both in cardiac flow simulators and the heart itself.
Journal: Bio-Medical Materials and Engineering, vol. 10, no. 2, pp. 83-124, 2000
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]