Article type: Research Article
Authors: Ferdous, Zannatul | Luo, Yunhua; ;
Affiliations: Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada | Department of Anatomy, Southern Medical University, Guangzhou, China
Note: [] Address for correspondence: Yunhua Luo, Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada R3T 2N2. E-mail: [email protected]
Abstract: A number of factors may have effects on hip fracture, for example, bone mineral density (BMD), body weight and height, femur length, femoral neck length, etc. It is not clear which factor(s) has the dominant effect on hip fracture. Therefore, the factors were investigated by a previously developed DXA (dual energy X-ray absorptiometry) based finite element model. The finite element model is patient-specific, as all information required in constructing the model was extracted from the patient's hip DXA image. DXA images of 180 patients were obtained from the Manitoba Bone Mineral Density Database. For each patient, a finite element model was constructed and fracture risk indices (FRI) were calculated at the three critical locations on the hip, i.e. the femoral neck, the intertrochanter and the subtrochanter. Possible correlations between the fracture risk indices and the factors were then investigated. The obtained results indicated that, for hip fractures resulted from lateral fall, areal BMD and patient's body weight are two dominant factors, but effects from the other factors are not trivial. The study suggested that hip fracture is the result of combined effects from all the factors. Therefore, use of areal BMD alone in clinical assessment of fracture risk is not reliable.
Keywords: Hip fracture risk, dual energy X-ray absorptiometry (DXA), bone mineral density (BMD), finite element model, fracture factors
DOI: 10.3233/BME-151271
Journal: Bio-Medical Materials and Engineering, vol. 25, no. 2, pp. 213-220, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]