Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Broadband Multimedia Sensor Networks in Healthcare Applications
Article type: Research Article
Authors: Liu, Brent J.; | Zhou, Zheng | Gutierrez, Marco A. | Documet, Jorge | Chan, Lawrence | Huang, H.K.
Affiliations: Image Processing and Informatics (IPI) Laboratory, Department of Radiology, University of Southern California, USA | InCor, University of São Paulo, São Paulo, Brazil | Hong Kong Polytechnic University, Hong Kong
Note: [] Corresponding author.
Abstract: Internet-2 is an advanced high-speed computer network, which has been widely used for medical imaging applications such as teleradiology and teleconsultation. Internet-2 can fulfill the requirements for high-speed data transmission and short turn-around time with low operation cost once installed. However, high performance may not necessarily be retained for global access from international network peers as well as commercial Internet Service Provider (ISP) solutions. This paper describes the methodology of establishing international Internet-2 connections between three different internationally linked sites: the Imaging Processing and Informatics (IPI) Laboratory, University of Southern California, Los Angeles, California; the Hong Kong Polytechnic University (PolyU), Hong Kong, and the Heart Institute (InCor) of the University of São Paulo, Brazil. Two major factors will be discussed including network looping in the US and bottleneck of the connection, raising the round-trip time and limiting the available bandwidth respectively. In addition to the three site International Internet2 Connectivity, a consistent and repeatable tuning protocol for international Internet2 applications in the clinical environment will be presented. The experimental results of the FTP and DICOM transmission using the automatic tuning protocol at both sending and receiving sites will be presented and compared with results for the combinations where this protocol is used at either one site only or no site at all in order to demonstrate the improvement in overall network throughput by this proposed tuning method. These performance numbers will also be compared to commercially available ISP connections to further show the differences between International Internet-2 and its ability to support medical imaging applications.
Keywords: International Internet-2 connectivity, research networks, bandwidth, automatic tuning protocol, PACS, DICOM compliance
Journal: Journal of High Speed Networks, vol. 16, no. 1, pp. 5-20, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]