Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Proceedings of the European Society for Clinical Hemorheology (E.S.C.H.), 26–29 June, 2005, Siena, Italy
Article type: Research Article
Authors: Travagli, Valter; | Zanardi, Iacopo | Boschi, Letizia | Turchetti, Vera | Forconi, Sandro
Affiliations: Dipartimento Farmaco Chimico Tecnologico, Università degli Studi di Siena, Italy | Dipartimento di Medicina Interna, Cardiovascolare e Geriatrica, Università degli Studi di Siena, Italy
Note: [] Corresponding author: Valter Travagli, Dipartimento Farmaco Chimico Tecnologico, Università degli Studi di Siena, Via Aldo Moro, 2, 53100 Siena, Italy. Tel.: + 39 0577 234317; Fax: + 39 0577 234333; E-mail: [email protected].
Abstract: Clinical measurement of blood viscosity is an important parameter in the diagnosis of different diseases (e.g., diabetes, hypertension, cardiovascular diseases). The significance of blood viscosity in the microcirculatory flow is also of great importance. Thus, a simple and accurate evaluation of hemorheological properties could be an important challenge in clinical practice. Nowadays, validated measurements of plasma viscosity are commonly carried out with rotational viscometers by means of the various geometric configurations. However, red blood cells deform under mechanical force and this aspect could lead to an artificial variation in the apparent viscosity. In this work, an evaluation of a new technique for the viscosity determination is focused. In particular, a torsional oscillation viscometer was adopted (VM10AL, CBC Europe) in the presence and in the absence of stirring conditions at thermostated conditions. The profile of the rheological behaviour as a function of time was recorded and compared with that obtained using a cone-plate rotational viscometer (AR300, TA Instrument).
Keywords: Blood viscosity, torsional oscillation viscometer
Journal: Clinical Hemorheology and Microcirculation, vol. 35, no. 1-2, pp. 283-289, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]