Abstract: Hemorheological and hemodynamic effects of high molecular weight polyethylene oxide (PEO) solutions have been studied in vitro and in vivo at 30 experimental dogs. The rheological behaviour of the PEO solutions and of blood samples has been assessed by rotational viscometers at 20°C, 25°C and 37°C. An addition of PEO solutions to the blood in vitro has modified its rheological behavior, depending on the shear rates, concentration and temperature. Saline with aqueous PEO solutions at the concentration of 500 ppm has been infused into the blood circulation of the experimental dogs to achieve the total concentration in blood of 20–30 ppm. The following parameters cardiac output, mean arterial blood pressure, central venous pressure, pulse frequency, blood volume flow in the femoral artery, total vascular resistance and blood viscosity before and after the infusion of PEO solutions have been studied. The main observed effect was a decrease of the hemodynamic resistance in the cardiovascular system up to 40% below the baseline after infusion of PEO solutions.
Keywords: Polyethylene oxide solutions, hemorheology, hemodynamics
Journal: Clinical Hemorheology and Microcirculation, vol. 30, no. 3-4, pp. 381-390, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]