Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected proceedings of the 12th European Conference on Clinical Hemorheology, 22‐26 June 2003, Sofia, Bulgaria
Article type: Research Article
Authors: Piagnerelli, M.; | Zouaoui Boudjeltia, K. | Piro, P. | Brohee, D. | Vanhaeverbeek, M. | Vincent, J.L.;
Affiliations: Department of Intensive Care, Erasme University Hospital, Free University of Brussels, 1070‐Brussels, Belgium | Experimental Medicine Laboratory, ISPPC A.Vésale Hospital, 6110‐Montigny‐le‐Tilleul, Belgium
Note: [] M. Piagnerelli, M.D. is a recipient of a grant from the Erasme Foundation.
Note: [] Corresponding author: J.L. Vincent, MD, PhD, Department of Intensive Care, Erasme University Hospital, Free University Hospital, 808, route de Lennik, 1070‐Brussels, Belgium. Tel.: +32 2 5553380; Fax: +32 2 5554555; E‐mail: [email protected].
Abstract: Several recent in vitro studies have observed that alterations in red blood cell (RBC) rheology depend on sample temperature. This possibility could limit the in vivo validity of the assessment of RBC shape. We investigated the effects of sample temperature on RBC shape estimated by flow cytometry in septic patients compared with those of volunteers. 0.5 ml of blood was placed at 4°C, room temperature (20°C) or at 37°C. RBCs were analyzed at 30 minutes (T30) by flow cytometry and results compared to baseline measures. With the flow cytometry technique, the RBC shape of healthy volunteers shows a bimodal distribution related to the biconcave form. On this histogram, we calculated the second Pearson coefficient of dissymmetry – PCD – representing the asymmetry of this histogram. At baseline, RBC PCD was increased in septic patients representing a more spherical shape compared to volunteers (−0.73±0.18 versus −0.95±0.05; p=0.007). For both groups, RBC shape estimated by the flow cytometry technique was not modified by the temperature of the sample. We conclude that estimation of RBC shape by flow cytometry is not influenced by the temperature of the sample. The present study validates the flow cytometry technique to assess RBC shape in vitro.
Keywords: Red blood cell, flow cytometry, shape, temperature, sepsis
Journal: Clinical Hemorheology and Microcirculation, vol. 30, no. 3-4, pp. 463-466, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]