Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bartoli, V. | Albanese, B. | Manescalchi, P.G. | Mannini, L. | Pasquini, G.
Affiliations: Cattedra di Patologia Medica IV, University of Florence, Policlinico di Careggi, 50134 Florence, Italy
Note: [] Accepted by: Editor H. Schmid-Schönbein
Abstract: Experimental: Two anticoagulants were tested, K2-EDTA and lithium-heparin. Blood was collected in both glass and plastic tubes using EDTA and in glass tubes only when lithium-heparin was used in two forms: dry and in a dilute saline sample. EDTA anticoagulated blood samples collected in plastic tubes were stored at 4°C, room temperature and 37°C. Immediately after the venepuncture and 1, 2, 6 and 24 hours later the following tests were carried out: whole blood filtration (Reid et al., 1976) using Nuclepore Hemafil filters, blood and plasma viscosity at low and high shear rates (Contraves LS 30 and Brookfield LVT viscometers), blood cell counts, red cell indices (Coulter counter S plus) and hematocrit. The morphology of erythrocytes was studied by means of Scanning Electron Microscopy (SEM) .The specimens of red cells were obtained from the same samples that underwent rheological tests. Results: Using heparin as an anticoagulant, whole blood filtration was severely impaired or blocked and blood viscosity and hematocrit were higher than they were using EDTA. The rheological properties of blood were altered by the storage, even after 1 hour, and the alteration became progressively greater as a function of time. SEM observations contributed to clarifying the effect of anticoagulants and storage conditions on the rheological properties of blood showing several changes of red blood cell morphology.
Keywords: Anticoagulants, Blood storage, Blood filtration test
DOI: 10.3233/CH-1986-6208
Journal: Clinical Hemorheology and Microcirculation, vol. 6, no. 2, pp. 137-149, 1986
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]