Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yamamoto, Tokunori; | Hayashi, Koichi | Matsuda, Hiroto | Tomura, Yuichi | Ogasawara, Yasuo | Hashimoto, Reiji | Tada, Tetsuhiro | Tanaka, Hiroyoshi | Kajiya, Fumihiko
Affiliations: Department of Urology, Kawasaki Medical School, Okayama, Japan | Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Okayama, Japan | Department of Electronic Engineering, Okayama University of Science, Okayama, Japan | Department of Internal Medicine, School of Medicine, Keio University, Tokyo, Japan
Note: [] Corresponding author. Fax: +81 86 463 2975; E‐mail: [email protected]‐m.ac.jp.
Abstract: There have been developed several types of experimental techniques for evaluation of renal microcirculation. Although each methodology possesses excellent and unique characteristics, it requires substantial artificial manipulation that might alter the renal microvascular responsiveness. To circumvent such limitations of previous ex vivo or in vitro approaches to glomerular microcirculation, we have developed a pencil lens probe CCD intravital videomicroscopic system that allows us to evaluate both systemic hemodynamics and renal microcirculation. Furthermore, real time images of afferent and efferent arterioles as well as glomeruli can be continuously assessed, which would facilitate the functional characterization of these microvessels in vivo. Finally, the tapered nature of the CCD probe of this videomicroscopy may allow direct observation of the renal microvasculature in small animals. In conclusion, this novel technique is a valuable tool for unveiling the in vivo, in situ, and intact renal microvascular behavior, and may provide further approaches to the understanding of renal microcirculation.
Keywords: Glomerular microcirculation, afferent arterioles, efferent arterioles, videomicroscopy, visualization
Journal: Clinical Hemorheology and Microcirculation, vol. 23, no. 2,3,4, pp. 103-108, 2000
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]