Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Joern, H.; | Kahn, N. | Klein, B. | Schmid‐Schoenbein, H. | Rath, W.
Affiliations: Department of Obstetrics and Gynecology, Rhenish‐Westfalian Technical University, Aachen, Germany | Institute of Physiology, Rhenish‐Westfalian Technical University, Aachen, Germany
Note: [] Correspondence to: Dr.med. Hendrik Joern, Department of Obstetrics and Gynecology, Rhenish‐Westfalian Technical University, Pauwelsstr. 30, D‐52074 Aachen, Germany. Fax: +49 2405 84817; E‐mail: [email protected]‐aachen.de.
Abstract: Objective: The aim of the study was to examine the efficiency of a hemodilution (HD) therapy on the inter‐ and intravillous placental blood circulation in high‐risk pregnancies by applying the colour‐angio‐mode (CAM). Patients and methods: 24 patients were examined who had fetal growth retardation and/or pathological Doppler results. In all cases the hematocrit was >36%. The patients were given 500 ml Ringer solution and 500 ml HAES 10% intravenously per day; maternal heart rate and blood pressure were measured continuously. Prior to and after the therapy the same area of the placenta was examined using CAM; histograms demonstrating the distribution of the intensity values and summation values of the color pixels were calculated. Results: In 14 patients the fetal outcome was good. The histograms showed in 11/14 cases an increase of low intensity values indicating an improvement of the placental circulation. The summation value of the color pixels as measured by CAM was significantly increased after the therapy in these cases (p = 0.022). In 10 patients the fetal outcome was unfavorable. The histograms showed a decrease of the intensity values in 6/10 cases. There was no significant change in the summation values of the color pixels after the therapy (p = 0.139). Conclusions: CAM sonography demonstrated for the first time a local effect of the HD therapy within the placenta. In the positive case the placental blood circulation will improve and the pregnancy develops favourably (responder). In the negative case there is no change of the placental blood circulation and pregnancy must be terminated due to a pathological fetal heart rate tracing, fetal growth failure or hypertensive disorders (nonresponder).
Keywords: Ultrasonography, colour‐angio‐mode, fetal growth failure, hemodilution, hypertensive disorders in pregnancy, pregnancy complication
Journal: Clinical Hemorheology and Microcirculation, vol. 22, no. 3, pp. 205-213, 2000
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]