Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles from the 3rd Joint Meeting of The European Society for Clinical Hemorheology and Microcirculation (ESCHM) , The International Society for Clinical Hemorheology (ISCH) and The International Society of Biorheology (ISB), Regensburg, Germany, 28 – 30 September 2023
Guest editors: L. Prantl, A. Krueger-Genge and F. Jung
Article type: Research Article
Authors: Greiner, Barbaraa; * | Kaiser, Ulrichb | Hammer, Simonea | Platz Batista da Silva, Nataschaa | Stroszczynski, Christiana | Jung, Ernst Michaela
Affiliations: [a] Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany | [b] Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. med. univ. Barbara Greiner, Pediatric Radiology, Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Franz-Josef-Strauß Allee 11, Regensburg 93053, Germany. Tel.: +49 941 944 17492; E-mail: [email protected].
Abstract: AIM: To evaluate the usefulness of handheld ultrasound in comparison with high-end ultrasound for lesion evaluation before and after sclerotherapy in pediatric patients with venous malformations (VMs). MATERIAL AND METHODS: 10 pediatric patients prior to and after sclerotherapy were scanned by an experienced examiner using handheld ultrasound (Vscan AirTM) and high-end ultrasound (LOGIQ E9/E10) as reference. Patients with associated venous thromboses and intralesional aneurysms had been excluded. Results were interpreted independently by two readers in consensus. RESULTS: 10 patients (4-17 years; 10.0±4.32 years; female n = 6, male n = 4) with 10 VMs (4 of the head and neck region, 4 of the upper and 2 of the lower extremities) were examined. 7 phleboliths were detected. The average rating score achieved by the high-end device never was less than 4, by Vscan AirTM never less than 3. An exception was the assessment of AV fistulas. In comparison with the evaluation of variables examined, we found a significant difference between the high-end scanner and the handheld device regarding the achieved image quality. CONCLUSION: Vscan AirTM ultrasound device allows new possibilities for procedure planning and post-procedural control of pediatric patients with VMs.
Keywords: Handheld ultrasound, Vscan Air, pediatric, venous malformations
DOI: 10.3233/CH-238106
Journal: Clinical Hemorheology and Microcirculation, vol. 86, no. 1-2, pp. 121-131, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]