Article type: Research Article
Authors: Wang, Tianqi; 1 | Xu, Mingda | Xu, Changyu | Wu, Yuqing | Dong, Xiaoqiu; *
Affiliations: Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
Correspondence: [*] Corresponding author: Xiaoqiu Dong, Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, 150000 Heilongjiang, China. E-mail: [email protected].
Note: [1] First author: Tianqi Wang, Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin,150000 Heilongjiang, China. E-mail: [email protected].
Abstract: OBJECTIVE:To compare the diagnostic value of microvascular flow imaging (MVFI) with that of contrast-enhanced ultrasound (CEUS) for the analysis of blood flow in benign and malignant cervical lymph nodes. MATERIAL AND METHODS:As a prospective study, 95 cervical enlarged lymph nodes (43 benign and 52 malignant) were observed in 95 patients using conventional ultrasonography (including gray and Color Doppler Flow Imaging), CEUS, and MVFI. Two researchers evaluated vascular parameters of MVFI (vascular distribution, internal vascular features, vascular index) and CEUS (enhancement mode, enhancement type) and compared the diagnostic effects of MVFI and CEUS.All results were compared with pathological findings. RESULTS:There were significant differences in the vascular distribution and internal vascular features of benign and malignant lymph nodes on MVFI (P < 0.05). The vascular distribution of benign lymph nodes was mainly of the central and avascular types, the internal blood vessels were mostly normal, the vascular distribution of malignant lymph nodes was mainly mixed, the internal vessels were mainly tortuous and displaced. The optimal cut-off value of the benign and malignant lymph node vascular index (VI) was 15.55%, and the area under the receiver operating characteristic curve (AUC) of the VI was 0.876. There were also significant differences in the enhancement mode and types of benign and malignant lymph nodes in CEUS (P < 0.05). The benign lymph nodes showed centrifugal perfusion, and the enhancement types were mostly type I and type II. Most malignant lymph nodes showed centripetal or mixed perfusion, and the enhancement types were usually type III and type IV. The accuracy, sensitivity, and specificity of CEUS in the diagnosis of lymph node lesions were 84.2%, 84.6% and 83.7%, respectively, and the AUC was 0.845. The accuracy, sensitivity, and specificity of MVFI in the diagnosis of lymph node lesions were 85.3%, 84.6%, and 86.0%, respectively, and the AUC was 0.886. CONCLUSION:Both CEUS and MVFI are valuable in differentiating benign and malignant lesions of lymph nodes and have a similar diagnostic performance; however, MVFI is less invasive and simpler than CEUS. Therefore it is preferred for auxiliary examination of enlarged lymph nodes that are difficult to diagnose by conventional ultrasound.
Keywords: Conventional ultrasound, contrast-enhanced ultrasound, microvascular flow imaging, lymph nodes
DOI: 10.3233/CH-231860
Journal: Clinical Hemorheology and Microcirculation, vol. 85, no. 3, pp. 249-259, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]