Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Rasche, S.a; * | Trumpp, A.b | Waldow, T.a | Gaetjen, F.a | Plötze, K.a | Wedekind, D.b | Schmidt, M.b | Malberg, H.b | Matschke, K.a | Zaunseder, S.b
Affiliations: [a] Medizinische Fakultät, TU Dresden, Herzzentrum Dresden Universitätsklinik, Klinik für Herzchirurgie, Dresden, Germany | [b] Fakultät Elektrotechnik und Informationstechnik, TU Dresden, Institut für Biomedizinische Technik, Dresden, Germany
Correspondence: [*] Corresponding author: Stefan Rasche, Medizinische Fakultät, TU Dresden, Herzzentrum Dresden Universitätsklinik, Klinik für Herzchirurgie, Dresden, Germany. E-mail: [email protected].
Abstract: BACKGROUND: Camera-based photoplethysmography (cbPPG) is an optical measurement technique that reveals pulsatile blood flow in cutaneous microcirculation from a distance. cbPPG has been shown to reflect pivotal haemodynamic events like cardiac ejection in healthy subjects. In addition, it provides valuable insight into intrinsic microcirculatory regulation as it yields dynamic, two-dimensional perfusion maps. In this study, we evaluate the feasibility of a clinical cbPPG application in critical care patients. METHODS: A mobile camera set-up to record faces of patients at the bed site was constructed. Videos were made during the immediate recovery after cardiac surgery under standard critical care conditions and were processed offline. Major motion artefacts were detected using an optical flow technique and suitable facial regions were manually annotated. cbPPG signals were highpass filtered and Fourier spectra out of consecutive 10s signal segments calculated for heart rate detection. Signal-to-noise ratios (SNR) of the Fourier spectra were derived as a quality measure. Reference data of vital parameters were synchronously acquired from the bed site monitoring system. RESULTS: Seventy patient videos of an average time of 28.6±2.8 min were analysed. Heart rate (HR) was detected within a±5 bpm range compared to reference in 83% of total recording time. Low SNR and HR detection failure were mostly, but not exclusively, attributed to non-physiological events like patient motion, interventions or sudden changes of illumination. SNR was reduced by low arterial blood pressure, whereas no impact of other perioperative or disease-related parameters was identified. CONCLUSION: Cardiac ejection is detectable by cbPPG under pathophysiologic conditions of cardiovascular disease and perioperative medicine. cbPPG measurements can be seamlessly integrated into the clinical work flow of critical care patients.
Keywords: Camera-based Photoplethysmography, critical care patients, cutaneous microcirculation
DOI: 10.3233/CH-162048
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 1, pp. 77-90, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]