Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Potočnik, N. | Lenasi, H.*
Affiliations: Institute of Physiology, Medical Faculty, University of Ljubljana, Slovenia
Correspondence: [*] Corresponding author: Helena Lenasi, Institute of Physiology, Medical Faculty, University of Ljubljana, Zaloška 4, 1000 Ljubljana, Slovenia. Tel.: +386 1 5437513; Fax: +386 1 5437501; E-mail: [email protected].
Abstract: This study investigated the responses of skin blood flow (SkBF) in glabrous and nonglabrous skin to graded submaximal dynamic exercise and its recovery. We enrolled eight healthy young men with comparable maximal oxygen uptake (VO2max). Laser-Doppler flux (LDF) was assessed on the finger pulp (glabrous site) and the volar forearm (nonglabrous site) simultaneously with skin temperature, heart rate and blood pressure; cutaneous vascular conductance (CVC) was calculated. Subjects were monitored before (baseline), during and 25 minutes after incremental cycling. CVC in the pulp decreased with the onset of exercise (0.53±0.09AUmmHg–1 vs. baseline 1.23±0.25AUmmHg–1, p = 0.006), and persisted low until exercise cessation, whereas CVC in the forearm started to increase at 60% of subjects’ VO2max, attaining its maximum at the highest exercise load (0.44±0.11AUmmHg–1 vs. baseline 0.12±0,03AUmmHg–1, p = 0.017). In the recovery, CVC in the pulp attained a higher plateau value compared to baseline (1.51±0.22AUmmHg–1, p = 0.021), interrupted by abrupt transient falls of CVC. On the forearm, CVC subsequently returned to its baseline. SkBF of glabrous and nonglabrous sites adjust in an opposite manner to graded exercise load and also differ during recovery.
Keywords: Skin microcirculation, laser Doppler fluxmetry, arterio-venous anastomoses, submaximal graded exercice, recovery to exercise, glabrous skin, nonglabrous skin, cutaneous vascular conductance
DOI: 10.3233/CH-162045
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 1, pp. 65-75, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]