Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 38th Conference of the German Society for Clinical Microcirculation and Hemorheology, 21-23 November 2019, Braunschweig, Germany
Guest editors: P. Wiggermann, A. Krüger-Genge and F. Jung
Article type: Research Article
Authors: Grambow, Eberharda; * | Dau, Michaelb | Sandkühler, Niels Arnea | Leuchter, Matthiasa | Holmer, Amadeusc | Klar, Ernsta | Weinrich, Maltea
Affiliations: [a] Department for General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany | [b] Department of Oral, Maxillofacial and Plastic Surgery, University Medical Center Rostock, Rostock, Germany | [c] Diaspective Vision GmbH, Am Salzhaff, Germany
Correspondence: [*] Corresponding author: Eberhard Grambow, Department for General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany. Tel.: +49 381 494 6085; Fax: +49 381 494 2502; E-mail: [email protected].
Abstract: BACKGROUND:Objective, reliable and easy screening for peripheral artery disease (PAD) is essential to confirm the diagnosis and initiate the respective treatment. Therefore, a new non-invasive hyperspectral camera (TIVITA® Tissue) was tested in patients with and without PAD. OBJECTIVE:It was hypothesized that the oxygenation parameters of the TIVITA® Tissue correlate to established modalities for detection of PAD and allow differentiation between individuals with and without PAD. METHODS:Evaluation of tissue oxygenation was performed in the angiosome of the medial plantar artery in 25 healthy young people and in 24 patients with and 25 patients without PAD in comparable age. Thereby, superficial oxygenation (StO2) and near-infrared (NIR) perfusion index were measured with the TIVITA® Tissue. Additionally, the ankle-brachial-index (ABI), the complaint free walking distance and the vascular quality of life were assessed and demographic data were obtained from all participants. RESULTS:TIVITA® Tissue analysis revealed significantly reduced StO2 and NIR perfusion index in PAD compared to healthy young participants and patients without PAD. StO2 and NIR perfusion index positively correlated with ABI, the complaint free walking distance and the vascular quality of life score. CONCLUSIONS:In summary, this new hyperspectral imaging camera bears great potential for PAD screening as well as for follow up.
Keywords: Hyperspectral imaging, vascular surgery, screening, perfusion imaging, skin microcirculation
DOI: 10.3233/CH-199215
Journal: Clinical Hemorheology and Microcirculation, vol. 73, no. 1, pp. 3-17, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]