Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wiesinger, I.a | Schreml, S.b | Wohlgemuth, W.A.a | Stroszczynski, C.a | Jung, E.M.a; *
Affiliations: [a] Institute of Radiology, University Hospital Regensburg, Franz-Josef-Strauss-Allee, Regensburg, Germany | [b] Institute of Dermatology, University Hospital Regensburg, Franz-Josef-Strauss-Allee, Regensburg, Germany
Correspondence: [*] Corresponding author: Ernst Michael Jung, MD, Institute of Radiology, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany. Tel.: +49 941 944 7410; E-mail: [email protected].
Abstract: AIM: Aim of this pilot-study was to quantify perfusion changes of vascular malformations before and after the first interventional treatment using contrast-enhanced ultrasound (CEUS). MATERIAL AND METHODS: 29 patients (10 male, 19 female) between 6 and 63 years (mean 28.1 years) with 12 arterio-venous (AVM) and 17 venous malformations (VM) were examined before and after their first percutaneous interventional treatment. CEUS was performed with a 2.4 ml bolus injection of sulfur-hexafluorid microbubbles, and a 6–9 MHz mulitfrequency transducer. A 60 sec cine sequence was recorded and regions of interest (10 mm×30 mm) were defined in the centre, and the margins of the vascular malformation as well as in the surrounding healthy tissue. Time Intensity Curves (TIC) were analysed, and Time to Peak (TTP) as well as Area under the Curve (AUC) were calculated. RESULTS: For VM there was a significant perfusion difference (p < 0.05) in AUC between centre and the surrounding tissue before (323.1 vs. 130.4 rU) and after treatment (331.0 vs. 106.9 rU). There was no significant difference for TTP in ROIs of VM (19.1 vs. 26.5 sec). After the treatment there was a significant decrease in AUC for all three regions in AVMs, and an increase in TTP for AVM. However TTP for AVM in the centre ROI still remained shorter than in the surrounding tissue even after therapy (20.9 vs. 25.4 sec). CONCLUSION: CEUS with TIC analysis is a promising imaging method for the evaluation of perfusion before and after percutaneous treatment of vascular malformations. AUC decrease indicates therapy-induced changes in perfusion of VM whereas an increase in TTP shows therapy-related changes in AVM.
Keywords: Contrast-enhanced ultrasound (CEUS), venous malformation, arterio-venous malformation, TIC analysis
DOI: 10.3233/CH-151962
Journal: Clinical Hemorheology and Microcirculation, vol. 62, no. 4, pp. 283-290, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]