Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Qiu, Yijie | Yang, Daohui | Zhang, Qi | Chen, Kailing | Dong, Yi; 1; * | Wang, Wen-Ping; 1
Affiliations: Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
Correspondence: [*] Corresponding author: Prof. Dr. Yi Dong, Ultrasound Department, Zhongshan Hospital, Fudan University, 180th Fenglin Road, Shanghai, 200032, China. Tel.: +86 021 64041990 2474; Fax: +86 021 64220319; E-mail: [email protected].
Note: [1] Yi Dong and Wen-Ping Wang contributed equally to the manuscript.
Abstract: OBJECTIVE:To evaluate the feasibility of vector flow imaging technique (V Flow) in measurement of wall shear stress (WSS) of common carotid arteries (CCA) in healthy adults and to provide the normal WSS values assessed by V Flow. METHODS & MATERIALS:This prospective study was approved by the Ethics Committee of our University. Eighty healthy adult volunteers were included (mean age 43.3 y, 47 females, 33 males). The volunteers were classified into three groups according to their age: group I (age 20 - 39 y), group II (age 40 - 59 y) and group III (age 60 - 80 y). Mindray Resona 8 ultrasound machine and a linear array transducer (3–9 MHz) was used, equipped with the updated V Flow function. Common carotid arteries of both sides were evaluated in three segments (initial segment, middle segment and near bifurcation segment). The WSS values of CCA were measured by two independent radiologists. The intraclass correlation coefficient (ICC) of observer reliability in WSS measurement was calculated. Inter-observer reproducibility was also evaluated with the 95% Bland-Altman limits of agreement (LOA). RESULTS:V Flow measurements were performed successfully in 79 volunteers (98.8 %, 79/80). The mean value of WSS in right CCA was (0.66±0.24) Pa, in left CCA was (0.66±0.18) Pa (P > 0.05). Mean WSS value had a moderately negative correlation with age group (P < 0.05). The mean WSS value of group I(mean±SD, 0.75±0.25 Pa) is larger than group II (mean±SD, 0.62±0.13 Pa) and group III (mean±SD, 0.49±0.11 Pa) (P < 0.05). The ICC of observer reliability of group I, II and III was 0.96 (95% confidence interval (95% CI) 0.92–0.98), 0.94 (95% CI 0.88–0.97), 0.93 (95% CI 0.76–0.98) respectively. The Bland-Altman plots showed that the 95% LOA were –0.17–0.12 (Pa) for group I, –0.09–0.13 (Pa) for group II and –0.08–0.10 (Pa) for group III. CONCLUSION:V Flow measurement is a simple, rapid and feasible imaging method for the WSS assessment of CCA in healthy volunteers, which will probably be an important tool for assessing CCA function.
Keywords: Vector flow imaging (V Flow), wall shear stress (WSS), common carotid artery (CCA), feasibility, normal value
DOI: 10.3233/CH-190719
Journal: Clinical Hemorheology and Microcirculation, vol. 74, no. 4, pp. 453-462, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]