Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Dong, Yi; 1 | Liu, Lingxiao; 1 | Cao, Qiong | Zhang, Qi | Qiu, Yijie | Yang, Daohui | Yu, Lingyun | Wang, Wen-Ping; *
Affiliations: Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
Correspondence: [*] Corresponding author: Prof. Wen-Ping Wang, Department of Ultrasound, Zhongshan Hospital, Fudan University 180 Fenglin Road, Shanghai, 200032, China. Tel.: +86 0 21 64041990 2474; Fax: +86 0 21 64220319; E-mail: [email protected].
Note: [1] Yi Dong and Lingxiao Liu contributed equally to the manuscript.
Abstract: BACKGROUND AND AIM:To evaluate the benefits of contrast-enhanced ultrasound (CEUS) with high frequency transducers in characterization of focal gallbladder lesions (FGL). MATERIAL AND METHODS:From January 2017 to April 2019, 59 FGL detected by B mode ultrasound (BMUS) were examined, first with the low frequency convex transducer (1–5 MHz) and afterwards with high frequency transducer (7.5–12 MHz). High frequency dynamic CEUS were applied after bolus injection of 4.8 ml Sulphur hexafluoride microbubbles (SonoVue®, Milan). The BMUS and CEUS imaging features were recorded and compared. All lesions were confirmed by surgical resection and histopathologic results. RESULTS:The final diagnoses of 59 FGL included gallbladder adenocarcinoma (n = 15), gallbladder polyps (n = 11), gallbladder adenomas (n = 18), focal adenomyomatosis (n = 9), and gallbladder Ascariasis debris (n = 6). The mean diameter of FGL was 24.5±11.4 mm, and mean depth to the abdominal wall was 21.2±7.3 mm. While applying CEUS with high frequency transducer, specific diagnostic features, including arterial phase irregular intralesional vascularity (10/15, 66.7%), late phase hypoenhancement (12/15, 80%), destruction of gallbladder wall (8/15, 53.3%), infiltration to the adjacent liver (6/15, 40.0%) were significantly higher in malignant FGL. The overall sensitivity, specificity and diagnostic accuracy for the correct characterization of malignant FGL were significantly improved by CEUS with high frequency transducer (sensitivity 93.3%, specificity 88.5%, accuracy 100%). CONCLUSION:With its superior contrast resolution, CEUS performed with high frequency transducers is helpful to achieve better visualization of gallbladder fundus and make differential diagnosis of gallbladder lesions, which might greatly improve diagnostic confidence between malignant and benign FGL.
Keywords: Contrast enhanced ultrasound (CEUS), focal gallbladder lesion, high frequency, diagnosis, differentiation
DOI: 10.3233/CH-190639
Journal: Clinical Hemorheology and Microcirculation, vol. 74, no. 2, pp. 167-178, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]