Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Presentations held at the 33th Annual Conference of the German Society for Clinical Microcirculation and Hemorheology, Villingen-Schwenningen, Germany, 14-15 November, 2014
Article type: Research Article
Authors: Zimmermann, H. | D'Anastasi, M. | Rjosk-Dendorfer, D. | Helck, A. | Meimarakis, G. | Reiser, M. | Clevert, D.A.
Affiliations: Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich-Grosshadern, Germany | Department of Surgery, Ludwig-Maximilians-University Hospital Munich-Grosshadern, Germany
Note: [] Shared first-authorship.
Note: [] Shared first-authorship.
Note: [] Corresponding author: Dirk André Clevert, MD, Professor of Radiology, Department of Clinical Radiology, Interdisciplinary Ultrasound Center, University of Munich – Grosshadern Campus, Marchioninistr. 15, 81377 Munich, Germany. Tel.: +49 89/44007 3620; Fax: +49 89/44007 8832; E-mail: [email protected]
Abstract: PURPOSE: To compare the value of high-resolution contrast-enhanced ultrasound in the detection and characterisation of endoleaks after EVAR. MATERIAL AND METHODS: In this retrospective study, a cohort of 80 patients underwent both standard examination using a curved array 5 MHz transducer and a second examination using a curved array 9 MHz transducer. The examination included B-mode, color Doppler and contrast-enhanced ultrasound using the Philips EPIQ 7 scanner. RESULTS: 80 patients were included in the study. CEUS was used as the preferred examination in determining the presence of an endoleak. The sensitivity and specificity for the detection of endoleak using the 5 MHz transducer was: CEUS (96.8%, 100%), Color Doppler (47.6%, 94.1%), B-mode (15.8%, 94.1%), while for the 9 MHz transducer: CEUS (100%, 100%), Color Doppler (39.7%, 94.1%), B-mode (23.8%, 24.1%). CONCLUSION: High resolution ultrasound (9 MHz) in detection and characterization of endoleaks after EVAR has some minor advantages in comparison to lower resolution ultrasound (5 MHz).
Keywords: Endoleak, EVAR, AAA, CEUS, high resolution ultrasound
DOI: 10.3233/CH-141896
Journal: Clinical Hemorheology and Microcirculation, vol. 58, no. 1, pp. 247-260, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]