Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers from the Neubrandenburg Conference, 8-9 June, 2018
Article type: Research Article
Authors: Fuhrmann, Irene; * | Brünn, Karin | Probst, Ute | Verloh, Niklas | Stroszczynski, Christian | Jung, Ernst Michael | Wiggermann, Philipp | Haimerl, Michael
Affiliations: Department of Radiology, University Hospital Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Irene Fuhrmann, Department of Radiology, University Hospital Regensburg, 93042 Regensburg, Germany. Tel.: +49 941 944 7401; Fax: +49 941 944 7402; Email: [email protected].
Abstract: BACKGROUND:The diagnostic value of Doppler ultrasonography of the portal vein for the evaluation of liver function is still contradictory. OBJECTIVE:Aim of this study was to test the relationship between clinical liver function tests based on MRI and breath testing and blood flow in the portal vein. METHODS:The portal vein velocity was measured by color coded Doppler ultrasonography (CCDS) and tested against the relative enhancement (RE), a MRI-based index of liver function. The signal intensity in the liver parenchyma was assessed before (pre) and after (post) administration of contrast agent, the RE was calculated afterwards. Further, the liver function was also assessed using a 13C-Methacetin-based breath test. The blood flow in the portal vein was tested for possible correlation applying Pearson’s correlation coefficient. RESULTS:Using CCDS, all patients show a hepatopetal portal blood flow. The portal vein velocity is decreasing with progression of liver damage and there was a significant correlation of portal velocity with SI post (r = 0.411, p = 0.024). However, the portal velocity did not correlate significantly with the 13C-MBT readout (r = 0.233; p = 0.216), SI pre (r = 0.271, p = 0.147) or the relative enhancement (r = 0.303; p = 0.103). CONCLUSIONS:The results of this proof-of-principle study indicate that CCDS-based assessment of portal velocity is of only limited value for the evaluation of liver function.
Keywords: 13C-methacetin liver function breath test, contrast enhanced MRI, doppler, liver function, portal vein velocity, signal intensity, sonography
DOI: 10.3233/CH-189323
Journal: Clinical Hemorheology and Microcirculation, vol. 70, no. 4, pp. 585-594, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]