Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Schleder, S.a; * | Janke, M.a | Agha, A.b | Schacherer, D.c | Hornung, M.b | Schlitt, H.J.b | Stroszczynski, C.a | Schreyer, A.G.a | Jung, E.M.a
Affiliations: [a] Department of Radiology, University Hospital Regensburg, Germany | [b] Department of Surgery, University Hospital Regensburg, Germany | [c] Department of Internal Medicine I, University Hospital Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. med. S. Schleder, Department of Radiology, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany. Tel.: +49 941 944 7401; Fax: +49 941 944 7402; E-mail: [email protected]
Abstract: Background:To evaluate the impact of high-resolution contrast-enhanced ultrasound (CEUS) in combination with Color Coded and Power Doppler Sonography (CCDS/PD) in the preoperative differentiation of thyroid adenomas and thyroid carcinomas. Methods:A total of 101 patients (55 female, median age 54 years) underwent surgery for thyroid adenoma and thyroid carcinoma. CCDS/PD and CEUS were performed in all patients by an experienced examiner using a multifrequency linear transducer (6–9 or 6–15 MHz) and were digitally stored. Reading of the ultrasound images was performed by two experienced radiologists in consensus. A histopathological evaluation was obtained as standard of reference in all patients. Results:Altogether, 75 thyroid adenomas and 26 thyroid carcinomas were detected. Mean diameter of thyroid adenomas and thyroid carcinomas was 27 mm and 32 mm, respectively. The differences in microcirculation of thyroid adenomas and thyroid carcinomas were statistically highly significant (p < 0.01). Representative features for thyroid adenomas were either no wash-out or wash-out with persisting edge in late phase, for thyroid carcinomas a complete wash-out in late phase. Thus, a calculation of sensitivity, specificity, positive and negative predictive value of 81% , 92% , 97% and 63%, respectively, for the differentiation of benignity and malignancy was possible. Conclusions:Dynamic evaluation of microcirculation using CEUS and CCDS/PD enables a more reliable preoperative discrimination between thyroid adenomas and thyroid carcinomas.
Keywords: Ultrasound, CEUS, Power Doppler Sonography, thyroid adenoma, thyroid carcinoma
DOI: 10.3233/CH-141848
Journal: Clinical Hemorheology and Microcirculation, vol. 61, no. 1, pp. 13-22, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]