Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Prantl, L. | Englbrecht, M.A. | Schoeneich, M. | Kuehlmann, B. | Jung, E.M. | Kubale, R.
Affiliations: Center for Plastic, Aesthetic, Hand & Reconstructive Surgery, University Hospital Regensburg, Regensburg, Germany | Department of Radiology, University Hospital Regensburg, Regensburg, Germany | Institute of Radiology, Nuclear Medicine and Sonography, Hospital Pirmasens, Pirmasens, Germany
Note: [] Corresponding author: Lukas Prantl, MD, PhD, Center of Plastic-, Hand- and Reconstructive Surgery, 93042 Regensburg, Germany. Tel.: +49 941 944 6947; Fax: +49 941 944 6948; E-mail: [email protected]
Abstract: BACKGROUND: To estimate the presence and severity of capsular contracture in patients after breast implants an objective measurement tool is necessary. PATIENTS AND METHODS: Eleven patients (range of age 37 to 53 years) who underwent cosmetic breast augmentation (seven patients with bilateral implants) or breast reconstruction by mammary asymmetry (four patients unilateral) with smooth silicone gel implants were included in this prospective study. In total seventeen implants were examined clinically and with the colour coded Ultrasound Elastography using a multifrequency probe (5–10 MHz Siemens Antares Premium VFX13-5). The grade of capsular contracture was assessed by two examiners with the palpation method and classified according to the Baker score. The Ultrasound Elastography was performed by two radiologists specialized in breast imaging and was correlated with the Baker score, colour coded ultrasound elastography and a high resolution ultrasound B-scan score (0–5). RESULTS: The clinical examination proved following distribution of the Baker degree: 6 breast implants with Baker grade I and Baker grade II, 3 breast implants with Baker grade III and two breast implants with Baker grade IV. There was a high correlation between the Baker score and the objective scoring measured by Ultrasound Elastography (kappa 0.83–0.89). CONCLUSION: The new technology of Ultrasound Elastography represents a useful tool to evaluate the compressibility of the peri-implant capsule, the implant and the surrounding tissue.
Keywords: Capsular contracture, mammary compliance, ultrasound elastography, baker's classification
DOI: 10.3233/CH-141812
Journal: Clinical Hemorheology and Microcirculation, vol. 58, no. 4, pp. 521-528, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]