Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Hemostasis
Article type: Research Article
Authors: Braune, Steffen | von Ruesten-Lange, Maik | Mrowietz, Christof | Lützow, Karola; | Roch, Toralf; | Neffe, Axel T.; | Lendlein, Andreas; | Jung, Friedrich;
Affiliations: Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies, Helmholtz-Zentrum Geesthacht, Kantstrasse 55, 14513 Teltow, Germany | Helmholtz Virtual Institute – Multifunctional Biomaterials for Medicine, Teltow and Berlin, Germany
Note: [] Corresponding author: Prof. Dr. Friedrich Jung. Tel.: +49 3328 352 269; Fax: +49 3328 352 452; E-mail: [email protected]
Abstract: Linear, side-chain methylated oligoglycerols (OGMe) were recently reported as potential surface passivating molecules for improving the protein resistance of cardiovascular application relevant poly(ether imide) (PEI) membranes. A previously reported in vitro screening under static test conditions allowed an end-point evaluation of the adhesion and activation of adherent thrombocytes performed on the material surfaces and revealed similar levels of thrombogenicity on PEI membranes, functionalized with OGMe and oligo(ethylene glycol) (OEG) of similar molecular weight (Mn = 1,300 g·mol−1 - 1,800 g·mol−1). In the present study, we investigated the hemocompatibility of these materials in a dynamic closed loop system, in order to study time-dependent thrombocyte material interactions also of the circulating thrombocytes by mimicking in vivo relevant flow conditions in a dynamic test system with multiple material contacts. Activation and aggregation of circulating thrombocytes as well as complement activation and plasmatic coagulation were evaluated after 40 circulations of thrombocyte rich plasma in the closed loop system. The results of the dynamic tests revealed no differences between the OGMe and OEG functionalized PEI membranes. Furthermore, no differences were observed between the latter and a PEI membrane treated under the conditions of functionalization at pH 11 (PEI-pH11) without an oligoether being present. Blood plasma protein adsorption, as well as activation, and adherence of circulating thrombocytes occurred in a comparable, but minor manner on all investigated PEI membranes. From this we conclude that the OGMe and OEG surface functionalization did not lead to an improvement of the already good hemocompatibility of the PEI-pH11 membrane.
Keywords: Oligoglycerol, protein resistance, hemocompatibility, surface functionalization, membranes, biomaterial
DOI: 10.3233/CH-131729
Journal: Clinical Hemorheology and Microcirculation, vol. 54, no. 3, pp. 235-248, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]