Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Yinga; b | Xu, Hui-Xionga; * | Zhao, Chong-Kea | Li, Xiao-Longa | Bo, Xiao-Wana | He, Ya-Pinga | Liu, Bo-Jia | Wang, Dana | Ren, Wei-Weia
Affiliations: [a] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China | [b] Department of Medical Ultrasound, Ningbo Medical Treatment Center Lihuili Hospital, Ningbo, Zhejiang, China
Correspondence: [*] Corresponding author: Prof. Dr. Hui-Xiong Xu, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, No. 301 Yangchangzhong Road, Shanghai 200072, China. Tel.: +86 21 663010310; E-mail: [email protected].
Abstract: OBJECTIVE:To assess the performance of conventional high frequency ultrasound (US) and US elastography in diagnosis of complex cystic and solid breast lesions. METHODS:Ninety three lesions in 93 patients underwent conventional US and US elastography, including strain elastography, acoustic radiation force impulse (ARFI) imaging, and point shear wave speed (SWS) measurement. RESULTS:Pathological examination revealed 31 (33.3%) of the 93 lesions were malignant and the remaining 62 (66.7%) were benign. Multivariate analysis showed that elder patient (OR: 25.301), internal vascularity (OR: 4.518), and not circumscribed margin (OR: 3.813) were independent predictors for malignancy, while predominately cystic lesions (OR: 0.178) was a predictor for benign lesions (all p < 0.05). Invalid SWS measurement was occurred in 19 of 31 (61.3%) malignant lesions and 16 of 62 (25.8%) benign lesions, respectively (p < 0.05). The mean SWS value for malignant lesions was significantly lower than that for benign ones, being 1.60±0.63 m/s (range, 0.68–2.70 m/s) versus 2.33±0.77 m/s (range, 0.67–3.97 m/s) (p < 0.05). Areas under the ROC curve (Azs) for Breast Imaging Reporting and Data System (BI-RADS) assessment, strain elasticity score, ARFI imaging and valid point SWS measurement were 0.844, 0.734, 0.763 and 0.778,respectively. CONCLUSIONS:US BI-RADS category, strain elastography score, ARFI imaging patterns and point SWS measurement are useful for malignancy prediction of complex cystic and solid breast lesions. The result that SWS for malignant lesions is lower than benign one should be carefully interpreted since invalid SWS measurement is excluded for analysis. The true stiffness of malignant cystic and solid lesions should be further evaluated with a new generation of two-dimensional SWS imaging.
Keywords: Complex cystic and solid lesion, breast, ultrasound, elastography, Breast Imaging Reporting and Data System, acoustic radiation force impulse
DOI: 10.3233/CH-170252
Journal: Clinical Hemorheology and Microcirculation, vol. 69, no. 3, pp. 355-370, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]