Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 18th European Conference for Clinical Hemorheology and Microcirculation (ESCHM), 5-8 June, 2016, Lisbon, Portugal
Article type: Research Article
Authors: Marcon, J.a; * | Trottmann, M.a | Rübenthaler, J.b | Stief, C.G.a | Reiser, M.F.b | Clevert, D.A.b
Affiliations: [a] Department of Urology, Ludwig-Maximilians-University of Munich – Campus Grosshadern, Munich, Germany | [b] Department of Clinical Radiology, Ludwig-Maximilians-University of Munich – Campus Grosshadern, Munich, Germany
Correspondence: [*] Corresponding author: Julian Marcon, M.D., Department of Urology, Ludwig-Maximilians-University of Munich – Campus Grosshadern, Marchioninistr. 15, 81377 Munich, Germany. Tel.: +49 8944000; E-mail: [email protected].
Abstract: INTRODUCTION: Shear wave elastography (SWE) is a recent technique in the assessment of tissue elasticity. Different elastography techniques have been described over the years. Acoustic Radiation Force Impulse Imaging (ARFI) uses mechanical excitation of tissue to create detectable shear waves, a higher shear wave velocity being associated with an increased tissue stiffness. The Virtual Touch Tissue Imaging Quantification (VTIQ) method uses a mechanical push pulse as well, additionally creating a colour-coded map, in which tissue stiffness can be measured within a stored map on the ultrasound device after measurement. ARFI has been used in determining standard values in testes of a healthy study collective, VTIQ has already been used in the evaluation of unclear scrotal masses. Both techniques allow an operator-independent examination without application of mechanical pressure. The aim of this study was to determine whether there is a statistically significant difference between shear wave velocity values of both techniques in a healthy collective. MATERIAL AND METHODS: Twenty patients without known testicular pathology underwent standard B-mode sonography and additional shear wave elastography in the ARFI mode as well as the VTIQ technique of both testes using the Siemens Acuson S2000™ and S3000™ ultrasound devices (Siemens HealthCare, Erlangen, Germany). Measurements of shear wave velocity were performed in the upper pole, the central portion and the lower pole separately for each testis. Values were described in m/s. Statistical evaluation was performed using paired t-test analysis. RESULTS: We measured a mean shear wave velocity of 0.81 m/s using ARFI and 1.07 m/s with VTIQ. Shear wave velocities determined by VTIQ were all significantly higher than values gained in the ARFI mode. (p < 0.001 to p = 0.007). Values were between 0.22 and 0.29 m/s higher, when the examination was performed using VTIQ. CONCLUSION: ARFI and VTIQ elastography modes both proved to be feasible techniques in the assessment of testicular tissue elasticity. Consideration of higher values for VTIQ is important, when different elastography measurement results are compared, especially for the application of devices in a clinical setting, e.g. in the work-up of scrotal masses. A calculable factor for a comparison between both devices is desirable, but to be further assessed in largerstudies.
Keywords: Testis, ARFI, VTIQ, shear wave elastography, ultrasonography
DOI: 10.3233/CH-168052
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 4, pp. 721-728, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]