Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 18th European Conference for Clinical Hemorheology and Microcirculation (ESCHM), 5-8 June, 2016, Lisbon, Portugal
Article type: Research Article
Authors: Brun, Jean-Frédérica; * | Varlet-Marie, Emmanuelleb; c | Fédou, Christinea | Raynaud de Mauverger, Erica
Affiliations: [a] UMR CNRS 9214-Inserm U1046 « Physiopathologie & Médecine Expérimentale du Coeur et des Muscles – PHYMEDEXP », Unité d’Explorations Métaboliques (CERAMM), Université de Montpellier, Département de Physiologie Clinique,Hôpital Lapeyronie CHU Montpellier, France | [b] Institut des Biomolécules Max Mousseron (IBMM) UMR CNRS 5247, Université de Montpellier, Ecole Nationale Supérieure de Chimie de Montpellier, France | [c] Laboratoire de Biophysique & Bio-Analyses, Faculté de Pharmacie, Université de Montpellier, France
Correspondence: [*] Corresponding author: Jean-Frédéric Brun, UMR CNRS 9214-Inserm U1046, « Physiopathologie & Médecine Expérimentale du Cœur et des Muscles – PHYMEDEXP », Unité d’Explorations Métaboliques (CERAMM), Université de Montpellier, Département de Physiologie Clinique, Hôpital Lapeyronie CHU Montpellier, France. Tel.: +33 467338284; Fax +33 467338986; E-mail: [email protected].
Abstract: We investigated to what extent a prediction of the ‘ideal’ hematocrit based on individual hemorheological profile with an equation of viscosity is relevant in trained athletes, and how the agreement between theoretical and actual values is modified by changes in training volume and performance. Elite soccer players (national level: 18–32 yr, weight 61–83 kg, body mass index 20.9–25.8 kg/m2) were seen twice at one year interval. Hemorheologic parameters were measured with the MT90 viscometer and the Myrenne aggregometer the theoretical bell-shaped curve of hematocrit/viscosity ratio as a function of hematocrit was reconstructed with Quemada’s equation using actual plasma viscosity and red cell rigidity to predict hematocrit/viscosity at various hematocrit levels. RBC aggregation is correlated at baseline with fat mass (M1 = 0.552 p < 0.02) and changes in aggregation are related to changes in fat mass (M = 0.652, p < 0.05; M1 = 0.647, p < 0.05). Predicted and actual hematocrit are correlated (r = 0.644, p < 0.05) but exhibit discrepancies (mean difference –1% range [3.24 to 1.24]) and those discrepancies are inversely correlated to the level of predicted hematocrit (r = –0.912, p < 0.01), to systolic blood pressure (r = –0.626, p < 0.05), and to the overtraining score (r = –0.693, p < 0.05). After one year changes in hematocrit are a close reflect of the change in training volume (r = –0.877, p < 0.01) but are not correlated to fitness changes. Therefore in these athletes i) systemic hematocrit is close to its predicted ‘ideal value”, suggesting the accuracy of the prediction; ii) red cell aggregation is correlated to fat mass even in nonobese subjects; iii) hematocrit is lower than predicted by the model when markers of sympathetic tone (systolic blood pressure, overtraining score) are increased; iv) weekly training volume appears the main determinant of the reduction of hematocrit.
Keywords: Exercise, soccer, hematocrit/viscosity ratio, hemorheology, erythrocyte aggregation
DOI: 10.3233/CH-168014
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 4, pp. 799-808, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]