Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: He, Ya-Ping | Xu, Hui-Xiong | Li, Xiao-Long | Li, Dan-Dan | Bo, Xiao-Wan | Zhao, Chong-Ke | Liu, Bo-Ji | Wang, Dan | Xu, Hui-Xiong*
Affiliations: Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China
Correspondence: [*] Corresponding author: Hui-Xiong Xu, MD, PhD, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai 200072, China. Tel.: +86 21 66307539; E-mail: [email protected].
Abstract: OBJECTIVE: The aim of this study was to compare the diagnostic performance of two different 2D shear wave speed imaging techniques of Virtual Touch Tissue Imaging & Quantification (VTIQ) and Toshiba shear wave elastography (T-SWE) in predicting malignant thyroid nodules (TNs). MATERIALS AND METHODS: 75 TNs in 75 patients which were subject to both VTIQ and T-SWE examinations were enrolled and analyzed. Shear wave speed (SWS) values on VTIQ and T-SWE were computed (SWS_max, min, mean and median). Area under the receiver operating characteristic (AUROC) curve was obtained to assess the diagnostic performance. RESULTS: The AUROC for VTIQ was the highest with SWS_min whereas for T-SWE was SWS_max (0.774 versus 0.851; p > 0.05). The AUROC, sensitivity and negative predictive value (NPV) corresponding to SWS_max for VTIQ were significantly lower than those for T-SWE (0.717 versus 0.851, 61.5% versus 92.3% and 78.7% versus 94.3%; all p < 0.05). However, no significant differences were found between AUROC with SWS_min, SWS_mean, or SWS_median for VTIQ and SWS_max for T-SWE (all p > 0.05). CONCLUSION: In general, VTIQ is equal to T-SWE for diagnosis of TNs. In the clinical practice, the selection of SWS_max should be avoided in VTIQ whereas should be selected in T-SWE.
Keywords: Acoustic radiation force impulse, shear wave elastography, ultrasound, thyroid nodules, fine-needle aspiration, diagnostic performance
DOI: 10.3233/CH-16217
Journal: Clinical Hemorheology and Microcirculation, vol. 66, no. 1, pp. 15-26, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]