Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhao, Chong-Kea; b; c | Xu, Hui-Xionga; b; c; * | Lu, Fenga; b; c | Sun, Li-Pinga; b; c | He, Ya-Pinga; b; c | Guo, Le-Hanga; b; c | Li, Xiao-Longa; b; c | Bo, Xiao-Wana; b; c | Yue, Wen-Wena; b; c
Affiliations: [a] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China | [b] Thyroid Institute, Tongji University School of Medicine, Shanghai, China | [c] Shanghai Research Center for Thyroid Diseases, Shanghai, China
Correspondence: [*] Corresponding author: Hui-Xiong Xu, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, No 301, Yanchangzhong Road, Shanghai 200072, China. Tel.: +86 21 66307539; Fax: +86 21 66301031 (O); E-mail: [email protected].
Abstract: OBJECTIVE: To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). MATERIALS AND METHODS: 69 BTNs (mean volume 6.35±5.66 ml, range 1.00–25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150–T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). RESULTS: The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38–22.13 min) and 12612±4466 J (range, 6310–26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P < 0.05). The mean VRRs of all BTNs were 23.4%, 54.4% and 81.9% at the 1-, 3- and 6-month follow-up, respectively. All BTNs achieved therapeutic success in this series in that all had VRRs of >50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P < 0.05). CONCLUSION: The factors associated with initial ICA after RFA for BTNs were predominantly solid nodules, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with those with ICA.
Keywords: Radiofrequency ablation, contrast-enhanced ultrasound, incomplete ablation, ultrasound, thyroid
DOI: 10.3233/CH-16208
Journal: Clinical Hemorheology and Microcirculation, vol. 65, no. 4, pp. 393-405, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]