Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yao, Ming-hua | Wu, Rong* | Xu, Guang | Zhao, Li-xia | Liu, Hui | Pu, Huan | Fang, Yan
Affiliations: Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Yanchangzhong, Shanghai, China
Correspondence: [*] Corresponding author: Rong Wu, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, No. 301, Yanchangzhong road, Shanghai 200072, China. Tel.: +86 021 66307539; E-mail: [email protected].
Abstract: BACKGROUND: Virtual touch imaging quantification (VTIQ), a form of shear wave elastography, may help in the diagnosis of breast lesions. OBJECTIVE: We aimed to evaluate the diagnostic performance of combined VTIQ and conventional ultrasound (US), and assess the factors influencing VTIQ measurement. METHODS: From September 2014 to December 2014, 162 patients with breast lesions were examined by US and VTIQ to assess shear wave speed (SWS) and morphological characteristics (lesion shape, orientation, margin and echo pattern). The sensitivity, specificity and accuracy of VTIQ, US and VTIQ+US for the diagnosis of breast lesions was evaluated in comparison to pathological results. Factors influencing deviations in SWS measurements were assessed by logistic regression. RESULTS: The SWS cut-off between malignant and benign lesions was 3.73 m/s. The sensitivity, specificity and accuracy were: 98.07%, 55.96%, and 69.57% for US; 76.92%, 78.89% and 78.26% for VTIQ; and 98.07%, 84.40% and 88.82% for US+VTIQ. The two factors that influenced the SWS results were the lesion margin (odds ratio [OR], 16.363; 95% confidence interval [CI], 3.220–29.020) and vascularity (OR, 6.712; 95% CI, 1.358–9.072). CONCLUSIONS: The lesion margin and vascularity could affect the measurement of SWS as well as the experience of examiner. However, VTIQ is still a reliable method that provides valuable information in the differential diagnosis of breast lesions, and may reduce unnecessary biopsies.
Keywords: Elastography, breast cancer, VTIQ, ultrasound
DOI: 10.3233/CH-16188
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 2, pp. 223-233, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]