Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, Bao-Dinga; e | Xu, Hui-Xionga; b; c; d; * | Zhang, Yi-Fenga; b; c; d | Liu, Bo-Jia; b; c; d | Guo, Le-Hanga; b; c; d | Li, Dan-Dana; b; c; d | Zhao, Chong-Kea; b; c; d | Li, Xiao-Longa; b; c; d | Wang, Dana; b; c; d | Zhao, Shuang-Shuange
Affiliations: [a] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Nanjing Medical University, Shanghai, China | [b] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Educational Institute, Tongji University School of Medicine, Shanghai, China | [c] Thyroid Institute, Tongji University School of Medicine, Shanghai, China | [d] Shanghai Research Center of Thyroid Diseases, Shanghai, China | [e] Department of Medical Ultrasound, Affiliated Hospital of Jiangsu University, Zhenjiang, China
Correspondence: [*] Corresponding author: Hui-Xiong Xu, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Nanjing Medical University, Shanghai 200072, China. Tel.: +86 21 66307539; Fax: +86 21 66301031; E-mail: [email protected].
Abstract: BACKGROUND: Non-calcified thyroid nodules are relatively difficult to diagnose only relying on features of at conventional US images. OBJECTIVE: To investigate the diagnostic performances of conventional strain elastography (SE), acoustic radiation force impulse (ARFI) SE and point shear-wave speed (pSWS) measurement for non-calcified thyroid nodules. METHODS: A total of 201 non-calcified thyroid nodules in 195 patients were studied. They were examined with conventional ultrasound (US), conventional SE, ARFI SE and pSWS measurement. Their diagnostic performances and multivariable models were assessed with receiver operating characteristic (ROC) curve and logistic regression analyses respectively. RESULTS: There were 156 benign and 45 malignant non-calcified nodules proven by histopathology or cystology. The mean diameters of the nodules were 21.2±10.8 mm. Areas under receiver operating characteristic curve (AUCs) of elastography features (ranged, 0.488–0.745) were all greater than that of US (ranged, 0.111–0.332). At multivariate analysis, there were three predictors of malignancy for non-calcified nodules, including pSWS of nodule (odds ratio [OR], 34.960; 95% CI, 11.582–105.529), marked hypoechogenicity (OR, 16.223; 95% CI, 1.761–149.454) and ARFI SE grade (OR, 10.900; 95% CI, 3.567–33.310). US+SE+pSWS owned the largest AUC (0.936; 95% CI, 0.887–0.985; P < 0.05), followed by US+pSWS (0.889; 95% CI, 0.823–0.955), and the poorest was US (0.727; 95% CI, 0.635–0.819). CONCLUSIONS: ARFI SE and pSWS measurement had better diagnostic performances than conventional SE and US. When US combined with SE and pSWS measurement, it could achieve an excellent diagnostic performance and might contribute a better decision-making of FNA for non-calcified thyroid nodules.
Keywords: Ultrasound, strain elastography, acoustic radiation force impulse, point shear-wave speed measurement, elastography
DOI: 10.3233/CH-16178
Journal: Clinical Hemorheology and Microcirculation, vol. 65, no. 3, pp. 259-273, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]