Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles of the 30th Annual Conference of the German Society for Clinical Microcirculation and Hemorheology (DGKMH), 18–21 June, 2011, Munich, Germany
Article type: Research Article
Authors: Meier, J.K. | Prantl, L. | Müller, S. | Moralis, A. | Liebsch, G. | Gosau, M.
Affiliations: Department of Cranio-Maxillo-Facial Surgery, University Medical Centre, Regensburg, Germany | Center of Plastic-, Hand- and Reconstructive Surgery, University Medical Centre, Regensburg, Germany | PreSens GmbH, Regensburg, Germany
Note: [] J.K. Meier and L. Prantl contributed equally to the manuscript.
Note: [] Corresponding author: Lukas Prantl, MD, PhD, Center of Plastic-, Hand- and Reconstructive Surgery, 93042 Regensburg, Germany. Tel.: +49 941 944 6947; Fax: +49 941 944 6948; E-mail: [email protected] J.K. Meier and L. Prantl contributed equally to the manuscript.
Abstract: Background: Free tissue transfer in head and neck reconstructions has a very high success rate, but thrombotic vessel occlusion is still a serious complication occurring in up to 10% of all cases. Thus, a simple, fast and reliable monitoring system for free flaps would be of advantage. Objective: The aim of this study was to investigate whether free flap monitoring by measuring perfusion-dependent parameters is a suitable method for discovering vessel thrombosis in free flaps. Methods: 10 patients requiring tissue reconstruction after tumour surgery or because of chronic wounds were included in this study. 10 microvascular flaps were harvested and transplanted. Perfusion was determined by measuring a fluorescent oxygen sensor foil covering the flap's skin surface by means of a USB-handheld fluorescence microscope prototype. The sensor contained an oxygen reservoir which was consumed by the tissue corresponding to the perfusion status of the flap. Measurements were done before explantation, after successful anastomosis and 1 day after surgery. Results: Clinically well-perfused grafts showed slope values between 0.07 and 0.27 (mean: 0.18 ± 0.07), and clinically poorly perfused grafts showed slope values between 0.35 and 0.75 (mean: 0.52 ± 0.19). In the present study, we used a threshold slope value of 0.3 for differentiating between well-perfused and poorly perfused flaps. Conclusion: Flap monitoring via oxygen imaging by means of fluorescent sensor foils appears to be a fast, non-invasive, cost-effective and thus suitable method for analyzing flap perfusion with the additional advantage of aiding decision making on flap revision.
Keywords: Free flap, microvascular, pO$_{2}$ imaging, fluorescent optical sensor
DOI: 10.3233/CH-2011-1439
Journal: Clinical Hemorheology and Microcirculation, vol. 50, no. 1-2, pp. 13-24, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]