Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Presentations from the 29th Conference of the German Society for Clinical Hemorheolgy and Microcirculation, Freie Universität Berlin, Germany, 17–18 September 2010
Article type: Research Article
Authors: Clevert, D.-A. | Sommer, W.H. | Helck, A. | Reiser, M.
Affiliations: Department of Clinical Radiology, Klinikum Grosshadern, University of Munich, Munich, Germany
Note: [] Corresponding author: Priv.–Doz. Dr. med. Dirk–André Clevert, Associate Professor of Radiology, Interdisciplinary Ultrasound-Center, Department of Clinical Radiology, University of Munich – Grosshadern Campus, Marchioninistr. 15, 81377 Munich, Germany. Tel.: +49 89/7095 3650; Fax: +49 89/7095 8832; E-mail: [email protected]
Abstract: Purpose: The aim of the study was to evaluate whether contrast enhanced ultrasound (CEUS) can improve the visualization of in-stent restenosis after carotid stenting of the internal carotid artery (ICA) in comparison to color-coded duplex sonography (CCDS) and power Doppler. Material and Methods: The study included the follow up of thirty patients after carotid artery stenting (CAS). Intrastenotic flow detection and lengths of in-stent restenosis were the main criteria. A high-end ultrasound machine (Siemens, ACUSON, Sequoia or S2000™) with a multi-frequency linear 9 MHz or 15 MHz transducer was used to carry out contrast-enhanced ultrasound with SonoVue®. In cases of treatment of a high degree in-stent stenosis intra-arterial digital subtraction angiography (DSA) was used. Results: All patients were examined using all diagnostic ultrasound tools of the study. In five patients (17%) an in-stent restenosis of the internal carotid artery (ICA) was found. Two patients need a reintervention. The results show that the contrast enhanced ultrasound could improve the diagnostic assessment capabilities in comparison to CCDS and power Doppler for patients with in-stent restenosis after carotid stenting of the ICA. Conclusion: Contrast enhanced ultrasound is a reliable method for the evaluation of in-stent restenosis after carotid stenting of the ICA. CEUS provides a reduction in intrastenotic flow artefacts, resulting in better visualisation and detection of the complete length of the stenosis in comparison with CCDS and power Doppler. In order to elucidate hemodynamic changes, additional Doppler examinations are still necessary.
Keywords: Carotid artery, contrast enhanced ultrasound, in-stent restenosis
DOI: 10.3233/CH-2011-1400
Journal: Clinical Hemorheology and Microcirculation, vol. 48, no. 1-3, pp. 199-208, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]