Issue title: Selected Papers from the 28th Congress on Clinical Hemorheology and Microcirculation of the German Society, Munich, Germany, 20–21 November 2009
Article type: Research Article
Authors: Horster, S. | Mandel, P. | Zachoval, R. | Clevert, D.A.
Affiliations: Department of Internal Medicine II, University of Munich-Grosshadern Campus, Munich, Germany | Institute of Clinical Radiology, University of Munich-Grosshadern Campus, Munich, Germany
Note: [] Corresponding author: Dr. med. Sophia Horster, Department of Internal Medicine II, University of Munich-Grosshadern Campus, Marchioninistr. 15, 81377 Munich, Germany. Tel.: +49 89/7095 2504; E-mail: [email protected]
Abstract: Purpose: Acoustic Radiation Force Impulse Imaging (ARFI) is a new ultrasound elastography technology (Siemens ACUSON S2000 Virtual Touch™ Tissue Quantification), which is integrated in conventional ultrasound equipment. In preliminary studies, ARFI sheer wave speed (SWS) in liver tissue correlated well with transient elastography (TE) values and liver fibrosis stages. Materials and methods: Sixty-eight healthy male and female volunteers were measured with ARFI with two ultrasound tranducers, three measuring positions and during valsalva manoeuvre. A TE (FibroScan™, Echosens, France) was performed in 60 volunteers. Results: Volunteers had a mean age of 28 years and a mean BMI of 22.3. There was no significant difference of ARFI SWS between the 4C1 and 4V1 ultrasound probes in either intercostal or abdominal approach to liver segment 8 but a higher variance of ARFI SWS with the 4V1/abdominal compared to the intercostal approach (p = 0.0368). The 4C1/intercostal approach had the highest success rates (97.2%), comparable to those of TE (97.18%). Left liver lobe measurements obtained both significantly higher ARFI SWS and value variance (p = 0.0016 and p = 0.0198) compared to 4C1/intercostal approach. Mean ARFI SWS was 1.19 m/s (range 0.77–1.63). Mean TE was 5.39 kPa (range 3.3–9.0 kPa). Valsalva manoeuvre did not significantly alter ARFI SWS and variance. Skin-liver distance significantly influenced ARFI SWS (p < 0.05), while age and gender did not. Conclusion: These results might constitute a first impression of the chances of ARFI SWS to assess liver stiffness, especially in patients with liver diseases due to increased venous pressure.
DOI: 10.3233/CH-2010-1342
Journal: Clinical Hemorheology and Microcirculation, vol. 46, no. 2-3, pp. 159-168, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]