Article type: Research Article
Authors: Varlet-Marie, Emmanuelle; | Aloulou, Ikram | Mercier, Jacques | Brun, Jean-Frédéric
Affiliations: Laboratoire de Biophysique & Bio-Analyses, Faculté de Pharmacie, Université Montpellier I, France | INSERM ERI 25 Muscle et Pathologies, Service Central de Physiologie Clinique, Centre d’Exploration et de Réadaptation des Anomalies du Métabolisme Musculaire (CERAMM), CHU Lapeyronie, France
Note: [] Corresponding author: Dr. Jean-Frédéric Brun, MD, PhD, INSERM ERI 25 Muscle et Pathologies, Service Central de Physiologie Clinique, Centre d’Exploration et de Réadaptation des Anomalies du Métabolisme Musculaire (CERAMM), CHU Lapeyronie, 34295 Montpellier-cédex 5, France. Tel.: +04 67 33 82 84; Fax: +04 67 33 89 86; Telex: CHR MONTP 480 766; E-mail: [email protected]
Abstract: Bioelectrical impedancemetry has been used to evaluate hemorheological parameters in vitro but whole body impedance measurements are also correlated to some hemorheologic factors, due to their close relationship with determinants of electric properties of blood. In previous studies, we have determined a set of predictive equations for hematocrit, whole blood viscosity and plasma viscosity in both sedentary and trained individuals. In this study we aimed at verifying those findings and investigating for other equations in a sample of 62 subjects whose body composition was assessed with a multifrequency bioelectrical impedancemeter using low intensity at the following frequencies: 1, 5, 10, 50 and 100kHz. Viscometric measurements were done with a falling ball viscometer. Hematocrit was measured with microcentrifuge. We confirm that hematocrit was correlated with impedance measurements at 50 kHz (r=−0.671, p < 0.01), and describe a new predictive equation for RBC rigidity index «k» calculated with the equation of Quemada, (“k” index = 0.0003 Z50 + 1.2815; mean difference: −0.0506; 95% confidence interval of −0.0134 to 0.00324) that is also correlated with impedance measurements at 50 kHz (r = 0.526, p < 0.01). Although the precision of these formulae is not sufficient for allowing true «predictions» of hematocrit and red cell deformability, these findings confirm that factors of viscosity are to some extent reflected by whole body electric properties.
Keywords: Blood viscosity, plasma viscosity, hemorheology, erythrocyte deformability, erythrocyte aggregability
DOI: 10.3233/CH-2010-1268
Journal: Clinical Hemorheology and Microcirculation, vol. 44, no. 4, pp. 237-244, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]