Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers from the Regensburg Conference, Regensburg, Germany, 5–6 September 2008
Article type: Research Article
Authors: Hoepken, S. | Fuhrmann, R. | Jung, F. | Franke, R.P.; ;
Affiliations: GKSS-Forschungszentrum Geesthacht, Berlin–Brandenburg Center for Regenerative Therapies (BCRT), Campus Virchow–Klinikum der Charité, Universitätsmedizin Berlin, Teltow, Germany | Department of Biomaterial, Central Institute for Biomedical Technology, University of Ulm, Ulm, Germany
Note: [] Corresponding author: Prof. Dr. R.P. Franke, GKSS-Forschungszentrum Geesthacht GmbH, Kantstraße, 5514513 Teltow, Germany. Tel.: +49 3328 352 483; Fax: +49 3328 352 452; E-mail: [email protected].
Abstract: A variety of medical grade polymeric materials are used in tissue engineering and biomedical technology. Dense non-porous polymeric foils were used as substrates for endothelial cell layers. Half a the test samples (polymers and control materials) were seeded with bovine corneal endothelial cells (BCEC) which more or less covered the substrates with an extracellular matrix (ECM) in the consecutive culturing period. Afterwards the ECM covered as well as the uncovered materials were seeded with human umbilical venous endothelial cells (HUVEC). HUVEC seeded samples were cultured either under static or under dynamical conditions in a cone/plate rheometer with a mean low arterial shear stress of 8.2 dyn/cm2 to simulate the flow conditions in a coronary vein graft. With the exemption of polyvinyl chloride all other materials could be coated with ECM at least partially. Under static conditions the best results with respect to complete coverage with ECM and HUVEC were seen on polyester and polyurethane. Under shear load, however, the complete HUVEC layer together with the ECM detached from the polymer surface within a short time. ECM and HUVEC remained no longer than 43 minutes on anyone of the materials tested. The materials as supplied and tested were clearly not appropriate as implants in contact to the flowing blood.
Keywords: Endothelial cells, extracellular matrix, shear stress, vascular graft, polymers, biomedical materials
DOI: 10.3233/CH-2009-1230
Journal: Clinical Hemorheology and Microcirculation, vol. 43, no. 1-2, pp. 157-166, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]