Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Prantl, L.; | Schmitt, St. | Geis, S. | Tsui, T.Y. | Lamby, P. | Nerlich, M. | Kubale, R. | Zorger, N. | Herold, T. | Feuerbach, S. | Jung, E.M.
Affiliations: Institute of Trauma, Plastic and Reconstructive Surgery, University Hospital Regensburg, Germany | Institute of Diagnostic Radiology, University Hospital Regensburg, Germany | Institute of Radiology, Nuclear Medicine and Sonography, Hospital Pirmasens, Germany
Note: [] Corresponding author: PD Dr. Lukas Prantl, MD, PhD, Department of Plastic Surgery, Regensburg University, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany. Tel.: +49 941 944 6947; Fax: +49 941 944 6806; E-mail: [email protected].
Abstract: Purpose: Contrast harmonic ultrasound (CHI) with a linear transducer is a new diagnostic approach that allows dynamic and quantitative flow detection of tissue perfusion in microsurgery. The aim of the study was the evaluation of perfusion of the dermal and subdermal layers of microvascular tissue transplants with CHI in comparison to ICG-fluorescence angiography. Material and method: In a prospective clinical study Indocyanine-Green Fluorescence Video Angiography and Contrast Enhanced High Resolution Ultrasound (5–10 MHz; linear transducer; Logiq 9; GE) were used for evaluation of the microcirculation in 10 transplanted free parascapular flaps. Two regions were analysed, the centre of the flap and the region of the anastomosis. The perfusion patterns of both methods were compared. Results: The perfusion indexes measured by ICG-fluorescence angiography correlated very precisely in all patients with the quantitative perfusion curves of contrast-enhanced US with CHI. Two flaps with slow filling and low dye intensity showed low contrast enhancement in CHI with modified perfusion curves with slow increase. In two cases a reduced perfusion and filling were found. There were no statistical differences between the two diagnostic methods (p>0.01). Conclusion: CHI improves US detections of dermal and subdermal microcirculation in comparison to ICG fluorescence angiography. CHI is a new diagnostic method for postoperative monitoring of free flaps.
Keywords: Parascapular flaps, contrast harmonic ultrasound, fluorescence angiography, microcirculation
Journal: Clinical Hemorheology and Microcirculation, vol. 38, no. 2, pp. 105-118, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]