Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zorger, N.; | Jung, E.M. | Hamer, O.W. | Paetzel, C. | Schreyer, A. | Seitz, J. | Stehr, A. | Steinbauer, M. | Feuerbach, S. | Herold, T.
Affiliations: Department of Diagnostic Radiology, University of Regensburg, Klinikum, Germany | Department of Diagnostic Radiology, Klinikum Weiden, Germany | Department of Surgery, University of Regensburg, Klinikum, Germany | Department of Surgery, Krankenhaus der Barmherzigen Brueder Regensburg, Germany
Note: [] Corresponding author: Dr. Niels Zorger, PD, Department of Radiology, University of Regensburg, Klinikum, Franz-Josef-Strauss-Allee 11, D-93042 Regensburg, Germany. Tel.: +49 941 944 7401; Fax: +49 941 944 7402; E-mail: [email protected].
Abstract: Objective: Feasibility of intraarterial MR angiography of the renal arteries and comparison of the accuracy of intraarterial MR angiography with selective intraarterial digital subtraction angiography (DSA) for detection of stenoses. Materials and methods: Ten consecutive patients (mean, 68 years) with suspected renal artery stenosis underwent a digital subtraction angiography and an intraarterial gadolinium-enhanced MR angiography, performed on a 1.5-T system. For intraarterial MR angiography 60 ml diluted contrast agent (10 ml gadodiamide in 50 ml 0.9% saline solution) was injected through a conventional angiography catheter placed in the suprarenal abdominal aorta using a flow rate of 3.5 ml/s. A three-dimensional (3D) gradient-echo sequence was performed. Differences in the quantitative measurement of stenoses of lesions between DSA and intraarterial MR angiography were evaluated by three observers. Overall impression of the intraarterial MR angiography was documented on a four-point scale (1 = excellent to 4 = poor). Interobserver variability was calculated. Results: Intraarterial MR angiography of the renal arteries was feasible in all patients (100%) with a mean overall impression of all images of 1.8 (SD: 0.71). One of 9 accessory renal arteries was not visualized with intraarterial MR angiography. The overall sensitivity/specificity for detection of significant stenoses (≥50% stenosis) were 83%/87%. Interobserver variability of intraarterial MR angiography ranged between fair and substantial (0.359–0.622). Conclusion: Intraarterial MR angiography of the renal arteries in humans is feasible and has an acceptable sensitivity in detecting stenoses using injections of diluted contrast agent at concentrations as low as 17%.
Keywords: Magnetic resonance, vascular studies, gadolinium, angiography, contrast media, arteries, renal arteries, stenosis, obstruction
Journal: Clinical Hemorheology and Microcirculation, vol. 38, no. 2, pp. 97-104, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]