Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Travagli, Valter; | Zanardi, Iacopo | Boschi, Letizia | Gabbrielli, Alessandro | Mastronuzzi, Vita A.M. | Cappelli, Roberto | Forconi, Sandro
Affiliations: Dipartimento Farmaco Chimico Tecnologico, Università degli Studi di Siena, Italy | Dipartimento di Medicina Interna, Cardiovascolare e Geriatrica, Università degli Studi di Siena, Italy
Note: [] Corresponding author: Valter Travagli, Dipartimento Farmaco Chimico Tecnologico, Università degli Studi di Siena, Via Aldo Moro, 2, 53100 Siena, Italy. Tel.: +39 0577 234317; Fax: +39 0577 234333; E-mail: [email protected].
Abstract: The absence of a simple and clinically practical method to determine whole blood viscosity can partly justify why the medical community has been slow in realizing the significance of whole blood viscosity. For this reason, the availability of a technique able to evaluate blood viscosity in a rapid and direct manner is welcome. To evaluate the feasibility in hemorheological laboratory of a new torsional oscillation viscometer, it was compared with a conventional cone–plate system. The viscosity comparison has been related to hematocrit value both on whole blood and suspended blood in a saline solution. The results showed a good repeatability and reproducibility of the new equipment, with a best-fitting data of the hematocrit 0–100% range characterized by coefficient of determinations, r2>0.95. Furthermore, a comparison of whole blood viscosity as measured by the two instruments was done on blood samples collected from hospitalized patients. Reasonable agreement for the viscosity values was found between the two methods with linear determination coefficients between the two measurement methods comprised between r2=0.7329 and 0.9263, depending on shear stress phase and the corresponding shear rate.
Keywords: Blood viscosity, hematocrit, torsional-oscillation viscometer, rheometer
Journal: Clinical Hemorheology and Microcirculation, vol. 38, no. 2, pp. 65-74, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]