Article type: Research Article
Authors: Eugster, M. | Häusler, K. | Reinhart, W.H.;
Affiliations: Internal Medicine, Kantonsspital, CH-7000 Chur, Switzerland | Institute of Mechanical Systems, ETH Zürich, 8092 Zürich, Switzerland
Note: [] Corresponding author: W.H. Reinhart, MD, Department of Internal Medicine, Kantonsspital, CH-7000 Chur, Switzerland. Tel.: +41 81 256 63 05; Fax: +41 81 256 63 81; E-mail: [email protected].
Abstract: Viscosity measurements on very small capillary blood samples could be of considerable clinical interest. We have developed an oscillating viscometer for very small volumes, which consists of a glass capillary containing 7 μl of blood, which is part of an oscillating torsional resonator. The damping of the sinusoidal oscillations depends on the density and viscosity of the fluid, which allows blood viscosity measurements. The instrument was first evaluated in comparison with a standard blood viscometer (Contraves LS 30). Blood from healthy volunteers anticoagulated with EDTA was adjusted to hematocrit levels of 20, 30, 40, 50, and 60%, respectively. A strong correlation was found between hematocrit and oscillating viscosity (y=0.17x−2.05, r=0.969, p<0.0001) and between oscillating and conventional high shear viscosity (y=1.11x−0.62, r=0.971, p<0.0001). Blood viscosity measured in venous or capillary blood of normal subjects was similar (p=0.63). Bedside viscosity measurements on capillary blood drawn from a finger prick during routine blood glucose measurements in patients with diabetes mellitus showed lower blood viscosity than controls (3.62±0.87 vs 4.79±0.59 mPa.s, p=0.0007), which is in contrast to earlier publications, and may be explained by the lower hematocrit in our diabetic patients (34.7±6.0% vs. 43.1±1.9%, p<0.0001). Blood viscosity was independent of the actual glucose level (range 3–17 mmol/l). Capillary blood anticoagulated with EDTA was drawn by heel prick from 23 newborns. Blood viscosity was higher (5.66 ±2.47 mPa.s) than in adult controls (see above), which could be explained by the dependence on the higher hematocrit (46.4 ±8.6%). We conclude that viscosity measurements can be made on very small samples such as capillary blood from diabetic patients or newborn babies with this new oscillating viscometer. It remains to be determined if such new informations have clinical implications.
Keywords: Blood, diabetes mellitus, hematocrit, newborns, viscosity
Journal: Clinical Hemorheology and Microcirculation, vol. 36, no. 3, pp. 195-202, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]