Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Käßer, U. | Heimburg, P.
Affiliations: Robert-Bosch-Krankenhaus, Department of Cardiology Auerbachstr. 110, 7000 Stuttgart 50, Germany
Note: [] Accepted by: Editor H. Schmid-Schönbein
Abstract: In order to determine accuracy and precision of the oscillatory capillary rheometer (OCR-D), two Newtonian (water, ethyleneglycol) fluids and a Non-Newtonian (aqueous solution of polyacrylamides) fluid were used. In addition, the ranges of normal and pathological plasma viscosity (1.07–4.61 mPas) and of whole blood viscoelasticity (2.94–12.32 mPas for the viscous and 0–6.46 mPas for the elastic component) were determined in order to select the ranges of viscoelastic parameters for control materials of clinical interest. Mixtures of water and ethyleneglycol were examined to prove their suitability as control samples for plasma viscosity: mixtures in a ratio of 1 to 0.5 and 1 to 4 (v/v) are recommended. To control the measurement of viscoelastic parameters of whole blood, the Non-Newtonian fluid (PAA) and a commercially available red blood cell test suspension (Dia-HT2) were investigated for their precision parameters. For quality control of the viscous component both solutions are required, whereas PAA may also serve for control of the elastic component, Dia-HT2 is not appropriate due to very low elastic responses.
Keywords: blood viscoelasticity, plasma viscosity, quality control, oscillatory capillary rheometer
DOI: 10.3233/CH-1988-8115
Journal: Clinical Hemorheology and Microcirculation, vol. 8, no. 1, pp. 93-103, 1988
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]