Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nakano, Atushi | Komai, Yutaka | Seki, Junji | Quintos, Ricardo | Niimi, Hideyuki;
Affiliations: National Cardiovascular Center Research Institute, Osaka 565-8565, Japan | Department of Physiology, College of Medicine, University of the Phillipines Manila, Ermita, Manila, Philippines
Note: [] Corresponding author. E-mail: [email protected].
Abstract: Autologus veins have been used clinically as a bypass conduit for reconstruction of small arteries, but there are few data available for microvascular response to arteriovenous (AV) shunting. This study was aimed to evaluate microvascular hemodynamic changes induced by creating AV anastomosis in rat hindlimb. Using intravital fluorescence videomicroscopy, we measured velocities of red blood cells (RBCs) flowing in the microvascular network in the control state, in the occlusion state where the superficial femoral artery (SFA) was occluded, and in the AV shunting state where the AV anastomosis was opened after occlusion of SFA. RBC velocities were measured in 155 capillaries of 6 rats using a dual window method and a frame-by-frame technique. The mean velocity and the coefficient of variation were 0.61 mm/sec and 0.90 in the control state, 0.34 mm/sec and 1.30 in the occlusion state, 0.83 mm/sec and 1.24 in the AV shunting state, respectively. These indicated that hemodynamic heterogeneity among capillaries increased with decrease in mean velocity following the arterial occlusion, while the AV shunting augmented the heterogeneity with increase in mean velocity. Capillaries with low perfusion (<0.1 mm/sec) or high perfusion (>1.0 mm/sec) were 5.8% or 20.6%, 29.6 or 5.2%, and 22.6 or 30.3% out of all measured capillaries in the control, occlusion and AV shunting conditions, respectively. In conclusion, AV shunting increased capillary perfusion and also its spatial heterogeneity, preferentially inducing high velocity in the microvasculature.
Keywords: Arteriovenous shunting, capillary perfusion, heterogeneity, fluorescence videomicroscopy, red cell velocity, limb microcirculation, microvascular response
Journal: Clinical Hemorheology and Microcirculation, vol. 33, no. 1, pp. 29-39, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]