Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: van der Loo, Bernd | Kovacevic, Tamara | Krieger, Elisabeth | Banyai, Susanne | Banyai, Martin | Amann‐Vesti, Beatrice R. | Jagacic, Dorijan | Rousson, Valentin | Koppensteiner, Renate;
Affiliations: Division of Angiology, Department of Medicine, University Hospital Zurich, Switzerland | Department of Biostatistics, ISPM, University of Zurich, Switzerland
Note: [] Corresponding author: Renate Koppensteiner, MD, Professor of Medicine, Head Division of Angiology, University Hospital Zurich, Raemistrasse 100, CH‐8091 Zurich, Switzerland. Tel.: +41 1 255 2679; Fax: +41 1 255 4510; E‐mail: [email protected].
Abstract: Rheological abnormalities are well known in patients with peripheral arterial occlusive disease (PAOD). We wanted to determine whether rheological variables are related to restenosis after femoropopliteal percutaneous transluminal angioplasty (PTA). In 114 patients (62 men; median age 70 years) undergoing femoropopliteal PTA for symptomatic peripheral arterial occlusive disease (PAOD) plasma viscosity, red cell aggregation, whole blood viscosity, hematocrit, fibrinogen, platelet count, leukocytes and C‐reactive protein were determined the day after the procedure and at 1, 3, and 12 months. The primary endpoint was restenosis >50% documented by duplexsonography up to 12 months. Cox proportional hazards analysis was used to assess the risk of restenosis for postinterventional values of rheological variables. Forty‐eight patients (42%) developed restenosis at 12 months. Patients with restenosis had higher baseline plasma viscosity (PV) (medians, 1.71 vs. 1.65 millipascal seconds [mPa.s]; p=0.04) and lower platelet count (224 vs. 240×103/μl; p=0.03) than patients without restenosis. The hazard ratio (HR; 95% CI) of incident restenosis was 9.2 (1.12–76; p=0.03) for PV and 0.99 (0.99–1.0; p=0.07) for PLT. When examining jointly both high PV and low platelet count (PLT), patients with PV > 1.66 mPa.s and PLT < 233×103/μl (i.e. variables split at their respective median) had an increased risk of restenosis (log‐rank test p=0.01). Multivariate Cox proportional hazard analysis showed that plasma viscosity (p=0.02), low platelet count (p=0.01), lesion length (p=0.0037) and lack of hypertension (p=0.01) were associated with restenosis at 12 months. No associations were found between restenosis and the other rheological and inflammatory variables studied. Our data suggest that increased PV and low PLT contribute to restenosis after femoropopliteal PTA.
Keywords: Balloon angioplasty, restenosis, platelets, plasma viscosity, blood rheology, femoropopliteal segment
Journal: Clinical Hemorheology and Microcirculation, vol. 32, no. 2, pp. 159-168, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]