Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected proceedings of the 12th European Conference on Clinical Hemorheology, 22‐26 June 2003, Sofia, Bulgaria
Article type: Research Article
Authors: Brun, Jean‐Frédéric; | Aloulou, Ikram | Varlet‐Marie, Emmanuelle
Affiliations: Service Central de Physiologie Clinique, Centre d'Exploration et de Réadaptation des Anomalies du Métabolisme Musculaire (CERAMM), CHU Lapeyronie, Montpellier, France | Laboratoire de Pharmacocinétique Clinique, Faculté de Pharmacie, Université Montpellier I, France
Note: [] Corresponding author: Dr J.F. Brun, MD, PhD, Service Central de Physiologie Clinique, Centre d'Exploration et de Réadaptation des Anomalies du Métabolisme Musculaire (CERAMM), CHU Lapeyronie, 34295 Montpellier‐cédex 5, France. Tel.: +33 04 67 33 82 84; Fax: +33 04 67 33 89 86; Telex: CHR MONTP 480 766 F; E‐mail: [email protected].
Abstract: Among hemorheologic parameters, plasma viscosity is one of the most studied in epidemiology, so that it has emerged as an independent risk factor. In diabetes, plasma viscosity is frequently elevated. For this reason we tried to define characteristics of non‐insulin dependent diabetics with high plasma viscosity (>1.45 mPa.s) and whether they were more insulin resistant and/or exhibited other hemorheologic disturbances. 12 subjects (age 56.1±11.7; BMI 28.6±4.8) were thus found to have a value of plasma viscosity >1.45 mPa.s. They were compared to 20 age and BMI‐matched NIDDMs. Patients have similar insulin sensitivity, HbA1c, and fibrinogen. RBC aggregation, rigidity and hematocrit were not significantly different. Whole blood viscosity at high shear rate was slightly higher (p=0.05). When corrected for hematocrit whole blood viscosity is no longer different. However, hematocrit was not lower in subjects with hpl >1.45. By contrast blood pressure was markedly higher (systolic: 177.5±2.5 mmHg vs 140±8 mmHg, p<10−8; diastolic 110±14 vs 83±9 mmHg, p<10−9; mean 132±18 mmHg vs 102±7 mmHg p<10−9). Therefore, in NIDDM, higher plasma viscosity, regardless insulin resistance and adiposity, is strongly related to blood pressure.
Keywords: Blood viscosity, plasma viscosity, hemorheology, erythrocyte deformability, erythrocyte aggregability, insulin sensitivity, insulin resistance, minimal model, arterial hypertension
Journal: Clinical Hemorheology and Microcirculation, vol. 30, no. 3-4, pp. 365-372, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]