Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected proceedings of the 12th European Conference on Clinical Hemorheology, 22‐26 June 2003, Sofia, Bulgaria
Article type: Research Article
Authors: Shin, Sehyun; | Ku, Yunhee | Park, Myung‐Su | Suh, Jang‐Soo
Affiliations: School of Mechanical Engineering, Kyungpook National University, Daegu, Korea | Department of Clinical Pathology, Kyungpook National University, Daegu, Korea
Note: [] Corresponding author: Sehyun Shin, School of Mechanical Engineering, Kyungpook National University, 1370 Sankyuk‐dong Buk‐gu, Daegu 702‐701, Korea. Fax: +82 53 956 9914; E‐mail: [email protected].
Abstract: A newly designed pressure‐scanning capillary viscometer is extended to measure the viscosity of whole blood over a range of shear rates without the use of anticoagulants in a clinical setting. In the present study, a single measurement of pressure variation with time replaces the flow rate and pressure drop measurements that are usually required for the operation of a capillary tube viscometer. Using a pressure transducer and capillary, we measured the variation of pressure flowing through capillary tube with respect to time, p(t), from which viscosity and the shear rate were mathematically calculated. For water and anticoagulant‐added bloods, there was an excellent agreement found between the results from the pressure scanning capillary viscometer and those from a commercially available rotating viscometer. Also, the pressure‐scanning capillary viscometer measured the viscosity of whole blood without heparin or EDTA. This new method overcomes the drawbacks of conventional viscometers in the measurement of whole blood viscosity. First, the pressure‐scanning capillary viscometer can accurately and consistently measure the whole blood viscosity over a range of shear rates in less than 2 min without any anticoagulants. Second, this design provides simplicity (i.e., ease of operation, no moving parts, and disposable) and low cost.
Keywords: Blood, viscosity, shear rate, pressure, capillary viscometer
Journal: Clinical Hemorheology and Microcirculation, vol. 30, no. 3-4, pp. 467-470, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]