Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Pasquini, G. | Morini, R. | Manescalchi, P.G. | Felici, G. | Albanese, B. | Bartoli, V.
Affiliations: Cattedra di Patologia Medica IV, University of Florence, Policlinico di Careggi, 50134 Florence, Italy
Note: [] Accepted by: Editor H. Schmid-Schönbein
Abstract: The smallest amount of stiff red cells which impairs the filterability of a whole blood sample is unknown. In order to answer such a question, an investigation was carried out on whole blood and red cell suspensions in plasma (Hct 0.10). A different amount of stiff red cells was added to these samples. The cells were rigidified by keeping the blood in thermostat at 37°C for 24–32 hours. The amount of incubated blood added to native blood and erythrocyte suspension was 10%, 5%, and 2.5%, respectively. Blood viscosity, hematological parameters and erythrocyte filtration were influenced by different amounts of stiffened red cells. When a blood sample containing 2.5 rigid cells per hundred was compared to a native blood sample, all hemorheological tests were unchanged except for erythrocyte filtration. This showed a significant delay in filtration times and a significant change of CFI. The filtering procedure appears to be the most sensitive test to reveal the presence of some stiff erythrocytes, but it is unable to show whether the delay in filtration rate is determined by a reduction of the flexibility of few, many, or all red cells in a blood sample.
Keywords: Erythrocyte filterability, Blood viscosity, Hematocrit
DOI: 10.3233/CH-1984-4507
Journal: Clinical Hemorheology and Microcirculation, vol. 4, no. 5, pp. 495-503, 1984
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]