Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jung, Ernst Michaela | Wiesinger, Isabelb | Kaiser, Ulrichc; * | Jung, Friedrichd
Affiliations: [a] Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany | [b] Department of Neuroradiology, Medbo District Hospital Regensburg, Regensburg, Germany | [c] Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Regensburg, Germany | [d] Institute of Biotechnology, Molecular Cell Biology, Brandenburg University of Technology Cott-bus-Senftenberg, Senftenberg, Germany
Correspondence: [*] Corresponding author: Dr. Ulrich Kaiser, Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Franz-Josef-Strauß Allee 11, 93053 Regensburg, Germany. E-mail: [email protected].
Note: [1] Selected article of the 42th Conference of the German Society for Clinical Microcirculation and Hemorheology, Senftenberg, Germany, 15–16 November 2024.
Abstract: BACKGROUND AND OBJECTIVE:Modern ultrasound technology enables detailed tissue morphology analysis. A novel approach involves measuring viscoelasticity or viscosity. This pilot study investigates the potential of a novel high-end ultrasound system with dynamic quality indicators and the M-Ref tool. METHODS:Using a novel premium high-end ultrasound system (Resona A20/Mindray), comparative investigations were conducted on 52 patients, evaluating B-mode morphology, shear wave tissue elastography (STE), and viscosity (STVi) of the liver parenchyma. The study utilized a cohort of 25 healthy volunteers as a control group. The examinations were performed intercostally using a multifrequency convex probe SC7-1U (1–7 MHz) and breath-hold technique, ensuring that at least the highest or second-highest score in the dynamic quality control (5 stars) was achieved. Measurements were made in a color-coded region with a maximum 2 cm diameter and a depth of no more than 2 cm, avoiding bile ducts or blood vessels, at a depth up 2 cm from the liver capsule. RESULTS:A minimum of 10 measurements were taken for each parameter: liver steatosis (based on acoustic attenuation coefficient, USAT), viscosity (STVi), and shear wave elastography (STE) with correlation to fibrosis grade. Reference values for the control group were <1.4 m/s and <5 kPa for STE, with cirrhosis criteria defined as values >2.6 m/s and >15 kPa. For steatosis, values up to 0.5 dB/cm/MHz were considered normal, while values >0.8 dB/cm/MHz indicated fatty liver. Viscosity values <1.7 Pa.s were deemed normal, with >3.6 Pa.s indicating significant abnormality. Major causes of increased viscosity included severe steatosis, active hepatitis, hepatic tumors, or post-ablative states. In all cases, a high-quality indicator score (>93%) was achieved with at least 4/5 top reference markers in green. CONCLUSIONS:This pilot study confirms the comprehensive capabilities of multimodal imaging for tissue characterization using B-mode, elastography, and new techniques for assessing viscoelasticity. However, extensive multicenter evaluations will be needed to definitively establish reference values specific to the type of transducer and equipment used.
Keywords: Liver ultrasound, quality indicators, shear wave elastography, viscosity, multiparametric (M-Ref)
DOI: 10.3233/CH-248111
Journal: Clinical Hemorheology and Microcirculation, vol. 88, no. 4, pp. 419-427, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]