Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wang, Yinga; 1 | Tian, Xiao-Fana; 1 | Cheng, Juana | Xu, Xin-Lianga | Cao, Jia-Yinga | Dong, Yia; * | Dietrich, Christoph F.b
Affiliations: [a] Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China | [b] Department Allgemeine Innere Medizin, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
Correspondence: [*] Corresponding author: Prof. Dr. med. Yi Dong, Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, 1665 Kongjiang Road, Shanghai, 200092, China. Tel.:+ 86 0 21 25076104; E-mail: [email protected].
Note: [1] These authors share the co-first authorship.
Abstract: OBJECTIVE: To evaluate pancreatic tissue stiffness and provide a normal reference shear wave velocity (SWV) value of pancreas from healthy adults by Virtual Touch Imaging Quantification (VTIQ) measurements. METHODS: Healthy adult volunteers without known history of hepatobiliary or pancreatic diseases were included. VTIQ elastography (Siemens ACUSON Sequoia, 5C-1 transducer) was used. SWV values were measured at the cephalic, corpus and tail of pancreas and replicated different operators’ obtained data. Subgroups were classified according to the volunteers’ gender, age, body mass index (BMI), depth of measurements and the echogenicity of the pancreas. RESULTS: From February 2023 to July 2023, 33 healthy adult volunteers were included. The success rate of VTIQ measurements in cephalic, corpus and tail regions was 90.90 % (30/33), 96.97 % (32/33) and 90.90 % (30/33) respectively. The color elastograms of healthy adult pancreas showed uniform blue or simultaneously blue and green. The average SWV values were 0.97±0.26 m/s for cephalic, 0.91±0.24 m/s for corpus and 0.97±0.25 m/s for pancreatic tail respectively (P = 0.198). The mean SWV values of pancreas did not show significant difference with age, gender or depth (P > 0.05). BMI was an influence factor in the measurements of SWV values of cephalic and tail of pancreas (P < 0.05). Pancreas with hyperechoic parenchyma showed higher mean SWV values (P < 0.05). The intra-observer (ICC = 0.938 [95% CI: 0.869–0.971]) and the inter-observer (ICC = 0.887 [95% CI: 0.760–0.947]) agreements of VTIQ measurements were excellent. CONCLUSIONS: The mean SWV value of the pancreas in healthy adults was 0.96±0.20 m/s (range: 0.52–1.74 m/s). VTIQ technique can be used in pancreatic stiffness measurements with good reliability.
Keywords: Shear wave velocity (SWV), ultrasound, pancreas, normal value, virtual touch imaging quantification (VTIQ)
DOI: 10.3233/CH-232092
Journal: Clinical Hemorheology and Microcirculation, vol. 87, no. 4, pp. 427-436, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]