Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liu, Linglinga; 1 | Chen, Linb; 1 | Zhao, Caihanc; 1 | Fan, Ruifangd | Tang, Qingc | Yuan, Qingc; * | Du, Weie; * | Liu, Xiangfuc; *
Affiliations: [a] Department of Hematology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, China | [b] Department of Stomatology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, China | [c] Department of Blood Transfusion, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, China | [d] Department of Prevention and Health, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, China | [e] Department of Neurosurgery, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, Henan, China
Correspondence: [*] Corresponding authors: Xiangfu Liu, Department of Blood Transfusion, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou, Guangdong Province, 510630, China. Tel.: +86 20 85252526; E-mail: [email protected] and Wei Du, Department of Neurosurgery, The First Affiliated Hospital, Zhengzhou University, No. 1 Jianshedong Road, Zhengzhou, Henan Province, 450052, China. E-mail: [email protected] and Qing Yuan, Department of Blood Transfusion, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou, Guangdong Province, 510630, China. E-mail: [email protected].
Note: [1] Lingling Liu, Lin Chen and Caihan Zhao contributed equally to the article.
Abstract: INTRODUCTION:This study retrospectively analyzed a total of 86 leukapheresis treatments in 55 patients with hyperleukocytic leukemia (HLL). METHODS:In the leukapheresis treatments, the monitoring collection (MNC) program in COBE spectra continuous flow centrifuge (CFC) for blood component separator was used. RESULTS:In this study, the white blood cell (WBC) suspension volume collected in leukapheresis treatment were 870.72±208.40 mL, and significantly larger than that reported in previous study. Compared with before leukapheresis, there were no difference in patient with HLL on the peripheral blood platelet (PLT) count and hemoglobin (HGB) levels. The index plasma fibrinogen (FIB) concentration was slightly reduced by leukapheresis, however, it did not affect a lot the maintenance of normal hemostatic function in patients with HLL. DISCUSSION:Our data provided evidences that large-volume leukapheresis had no obvious effects on HGB level and coagulation functions in patient with HLL. So large-volume leukapheresis by CFC could be widely used in clinic.
Keywords: Leukapheresis, hemoglobin, platelet, coagulation, hyperleukocytic leukemia
DOI: 10.3233/CH-231737
Journal: Clinical Hemorheology and Microcirculation, vol. 84, no. 3, pp. 275-281, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]