Authors: Stern, M.a; 1; * | Schremmer, J.a; 1 | Scharm, S.a | Baasen, S.a | Heinen, Y.a | Sansone, R.a | Polzin, A.a | Jung, C.a | Heiss, C.c; d | Kelm, M.a; b | Busch, L.a
Affiliations: [a] Department of Cardiology, Pulmonology, and Vascular Medicine, University Duesseldorf, Medical Faculty, Duesseldorf, Germany | [b] Cardiovascular Research Institute Duesseldorf (CARID)Duesseldorf, Germany | [c] Department of Clinical and Experimental Medicine, Faculty of Health and Medical Sciences, University of Surrey, Guildford, United Kingdom | [d] Department of Vascular Medicine, Surrey and Sussex NHS Healthcare Trust, Redhill, United Kingdom
Correspondence: [*] Corresponding author: Manuel Stern, MD., Department of Cardiology, Vascular Medicine, and pulmonary Diseases, University Duesseldorf, Medical Faculty, Moorenstreet. 5 40225 Duesseldorf, Germany. Tel.: +49 211 81 04424; Fax: +49 211 81 18812; E-mail: [email protected].
Note: [1] M. Stern and J. Schremmer contributed equally to this paper.
Abstract: BACKGROUND:Femoral pseudoaneurysm (PSA) is a severe complication after endovascular procedures. Ultrasound-guided manual compression (MC) and percutaneous thrombin injection (TI) are frequently used treatments. MC is less effective, TI may cause thromboembolic events. OBJECTIVE:Up to date, there is no data regarding impairment of microvascular tissue perfusion after PSA treatment. METHODS:In this single-center, prospective study 22 patients with PSA were included. We compared macro- and microcirculatory perfusion in the treated and untreated leg at baseline before, after and one day after treatment. Leg perfusion was assessed with ultrasound and ankle-brachial index (ABI). Microcirculatory perfusion of the feet was measured with a near-infrared spectroscopy (NIRS) camera generating StO2-tissue-maps. RESULTS:Successful PSA thrombosis was achieved in 16 (100%) patients in TI group and in 4 (66.7%) patients in MC group. There was no evidence of arterial thrombi on ultrasound and the ABI did not differ between groups. NIRS StO2-tissue-maps of the feet showed no significant difference in both groups concerning the treated (p = 0.121) or the untreated (p = 0.198) leg during follow up. CONCLUSIONS:In this small exploratory study, there was no evidence of micro- and macrovascular tissue perfusion impairment after treatment of postcatheterization femoral pseudoaneurysm with thrombin injection underscoring the safety of this approach.
Keywords: Microcirculation, tissue perfusion, femoral pseudoaneurysm, ultrasound-guided manual compression, ultrasound-guided percutaneous thrombin injection, near-infrared spectroscopy
DOI: 10.3233/CH-221438
Journal: Clinical Hemorheology and Microcirculation, vol. 82, no. 3, pp. 275-282, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]